Optimization-based adaptive optics for optical coherence tomography

2017· article· en· W2606418889 on OpenAlexfundno aff
Hans R. G. W. Verstraete

Bibliographic record

VenueResearch Repository (Delft University of Technology) · 2017
Typearticle
Languageen
FieldEngineering
TopicOptical Coherence Tomography Applications
Canadian institutionsnot available
FundersSimon Fraser University
KeywordsWavefrontAdaptive opticsWavefront sensorDeformable mirrorOptical coherence tomographyOpticsInterferometryOptical pathPhysicsLens (geology)Computer science

Abstract

fetched live from OpenAlex

Optical coherence tomography (OCT) is a technique for non-invasive imaging based on low coherence interferometry. Its main application is found in ophthalmology, where it is used for 3D in vivo imaging of the cornea and the retina. OCT has evolved over the past decade as one of the most important ancillary tests in ophthalmic practice, providing great diagnostic value for disease screening and monitoring. In retinal OCT imaging, the lateral resolution is not determined by the pupil size, but instead it is limited by optical wavefront aberrations of the cornea and lens. These aberrations reduce the OCT image resolution and lower the signal to noise ratio. To obtain high quality OCT images the optical aberrations can be removed using adaptive optics (AO).<br/><br/>In general, AO consists of an adaptive optical element and a wavefront sensor. The adaptive element, such as a deformable mirror, is used to reshape the wavefront and remove the undesired aberrations. The wavefront sensor measures the aberrations by reconstructing the phase of the wavefront, which is used to determine the correction on the wavefront applied by the deformable mirror. However, the use of a wavefront sensor has some disadvantages. It requires light being directed out of the imaging path onto the wavefront sensor. This leads to a loss of signal in the imaging path and can result in non-common optical path errors in the aberrations estimation procedure. Additionally, the use of a deformable mirror and a wavefront sensor leads to a bulky and expensive OCT setup.<br/><br/>The work presented in this thesis has the goal of reducing the cost and bulkiness of an AO-OCT system. First, we investigate the influence of optical wavefront aberrations to the OCT signal strength. The establishment of the relation between aberrations and the OCT signal strength is key to estimating and correcting the aberrations based on single OCT scans. By using Fresnel optical wave propagation and determining the fiber coupling efficiency, we find that the OCT transfer function, i.e. the function that expresses the relation between the aberrations and OCT signal strength, is quasi-convex. We determine both analytically and experimentally the transfer function for both reflective and scattering media, such as a mirror and Scotch tape sample. Additionally, if the OCT system and its optical properties are well-known we demonstrate a method to correct a defocus aberration in one step. <br/><br/>Second, we use the OCT transfer function to develop and determine an efficient wavefront sensorless (WFSL) AO optimization procedure. WFSL-AO methods aim to correct the aberrations without using a wavefront sensor, but instead base the determination of the wavefront on the imaging signal itself. This eliminates the use of the wavefront sensor, its extra cost and its disadvantages from an AO-OCT setup. To keep up with the OCT imaging rate, which is of the order of several tens of kHz, the algorithm has to be computationally efficient. Furthermore, there are no analytic derivatives available for the optimization and the OCT signal is very noisy. Finally, the derivative-free optimization algorithm also has to be able to determine the aberrations accurately when dealing with a minimum number of noisy measurements. We developed the Data-based Online Nonlinear extremum-seeker (DONE) algorithm. Every iteration, the DONE algorithm updates a surrogate function, which is based on random Fourier expansions (RFE) of the OCT transfer function, with a new OCT signal measurement. The optimum of the RFE surrogate function is then found with a well-known (quasi-Newton) optimization method. We demonstrate the effectiveness of the DONE algorithm compared to other optimization algorithms for WFSL-AO on biological and non-biological samples. We conclude that DONE has a smaller convergence error, while maintaining similar or faster convergence speeds compared to the other algorithms. <br/><br/>Third, we demonstrate a fully functional WFSL-AO OCT setup for retinal imaging. We use a state-of-the-art deformable lens with 18 actuators, rather than a deformable mirror, which leads to a smaller and more integrated WFSL-AO setup. The WFSL-AO OCT setup is successfully used for in vivo retinal OCT imaging and demonstrates that the DONE algorithm can remove the ocular wavefront aberrations with the deformable lens during in vivo OCT imaging. By developing a new algorithm and exploring the options for adaptive components, we have succeeded in retinal WFSL-AO OCT.<br/><br/>In a broader perspective, we show that the DONE algorithm is suitable for other applications than WFSL-AO OCT. We demonstrate that the DONE derivative-free optimization algorithm is robust towards noisy measurements for applications in robotics, microscopy and optical beam forming networks.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.604
Threshold uncertainty score0.782

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0010.002
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.033
GPT teacher head0.276
Teacher spread0.243 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueResearch Repository (Delft University of Technology)Same topicOptical Coherence Tomography ApplicationsFrench-language works237,207