Evaluation of the clinical safety and analytical reliability of blood glucose self-control tools "Glucocard Sigma" and "Glucocard Sigma-mini" in type 1 diabetes children.

2017· article· en· W2610516598 on OpenAlexaff
Екатерина Андреевна Андрианова, Aleksandr V. Il'yin, Tamara L. Kuraeva, Valentina Peterkova

Bibliographic record

VenueProblems of Endocrinology · 2017
Typearticle
Languageen
FieldMedicine
TopicDiabetes Management and Research
Canadian institutionsMcGill-Queen's University Press
Fundersnot available
KeywordsSix SigmaReliability (semiconductor)SigmaType 2 diabetesDiabetes mellitusReliability engineeringMedicineEngineeringPhysicsEndocrinologyOperations management

Abstract

fetched live from OpenAlex

Rationale. Arkray blood glucose meters have become widely used in Russia since 2013. Studies focused on their accuracy, where Arkray Glucocard II glucose meter is used as the reference monitoring system, have been published. Since insulin dose to be injected relies upon readings of a personal blood glucose meter, the system being used must comply with the clinical safety and analytical accuracy criteria for glucose meters.
 Objective — to assess clinical safety and analytical accuracy of the results of studying blood glucose level measured using Glucocard Sigma and Glucocard Sigma Mini blood glucose meters.
 Material and methods. Glucose level in a drop of capillary blood was studied in 48 pediatric and adolescent patients with type 1 diabetes mellitus (DMT1). The mean age of the patients was 9.4±5.6 years; average duration of the disease, 4.2±2.7 years. Parallel studies on glycaemia using the Glucocard Sigma and Glucocard Sigma Mini glucose meters being tested, as well as a BIOSEN C-line stationary biochemical analyzer system, were carried out at the Department of Diabetes Mellitus of the Institute of Pediatric Endocrinology and the Biochemical Laboratory of the Endocrinology Research Center of the Ministry of Healthcare of the Russian Federation. A total of 320 samples were examined. The hexokinase method performed on a BIOSEN C-line biochemical analyzer system was used as the reference method for measuring blood glucose level.
 Results. Assessment of clinical safety demonstrated that 100% of test results belonged to zone A (will not result in patient error) and B (will not result in patient error or there will be a minor error not affecting patient’s condition). These findings fully comply with the ISO 15197-2016 standard. Investigation of the analytical accuracy of Glucocard Sigma and Glucocard Sigma Mini glucose meters (capillary blood, glucose blood level >4.2 mmol/L) compared to the results obtained using the BIOSEN C-line biochemical analyzer system showed a <5% deviation in 118 (51.3%) measurements; <10%, in 202 (87.8%) measurements; less than 15%, 222 (96.5%) measurements; and less than 20%, in 230 (100%) measurements. These results comply both with the ISO 15197-2015 criteria and stricter criteria ISO 15197-2016.
 Conclusion. The high accuracy of Glucocard Sigma and Glucocard Sigma Mini glucose meters has been confirmed. The accuracy of these glucose meters complies with the State Standard GOST ISO 15197-2015 and the ISO 15197-2016 standard.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.006
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.030
Threshold uncertainty score0.694

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0040.006
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.048
GPT teacher head0.350
Teacher spread0.302 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueProblems of EndocrinologySame topicDiabetes Management and ResearchFrench-language works237,207