Integrated Lighting Efficiency Analysis in Large Industrial Buildings to Enhance Indoor Environmental Quality

2017· article· en· W2611788627 on OpenAlexafffund
Dušan Katunský, Erika Dolníková, Saeed Doroudiani

Bibliographic record

VenueBuildings · 2017
Typearticle
Languageen
FieldEngineering
TopicBuilding Energy and Comfort Optimization
Canadian institutionsNorth York General Hospital
FundersVedecká Grantová Agentúra MŠVVaŠ SR a SAVUniversity of TorontoSlovenská Akadémia Vied
KeywordsSkylightDaylightArchitectural engineeringDaylightingQuality (philosophy)Component (thermodynamics)Environmental scienceEnvironmental qualityProductivityArtificial lightEfficient energy useIndoor air qualityEngineeringCivil engineeringEnvironmental engineeringMechanical engineeringIlluminance

Abstract

fetched live from OpenAlex

We present observations from evaluation of internal environmental quality of industrial halls with priority on daylighting in combination with the integral lighting. The physical parameters related to indoor lighting in large industrial halls in winter and summer periods were analyzed using in situ measurements and computational methods. These are part of a comprehensive research on indoor environmental quality of industrial halls with the aims of saving energy and providing a comfortable environment for the workers while improving the productivity. The results showed that the procedures used for evaluation of residential or office buildings may not be used for industrial buildings. We also observed that the criteria of occupants’ comforts for indoor industrial buildings may differ from those of other kinds of buildings. Based on these results, an adequate attention is required for designing the industrial buildings. For this reason, appropriate evaluation methods and criteria should be created. We found the measured values of daylight factor very close to the skylight component of the total illumination. The skylight component was observed on average 30% that of the measured daylight factor values. Although the daylight is not emphasized when designing the industrial buildings and its contribution is small, but it is very important for the workers psychology and physiology. The workers must feel a connection with the exterior environment; otherwise, their productivity decreases.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.263
Teacher spread0.249 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations20
Published2017
Admission routes2
Has abstractyes

Explore more

Same venueBuildingsSame topicBuilding Energy and Comfort OptimizationFrench-language works237,207