MétaCan
Menu
Back to cohort
Record W2613793243 · doi:10.5539/ijc.v9n3p19

Optimized HPLC -UV Method for Separation, Detection and Quantification of Endocrine Disrupting Estrogens in Low Quality Water

2017· article· en· W2613793243 on OpenAlexvenueno aff
Sijaona Cassian Msigala, Faith Philemon Mabiki, Bjarne Styrishave, Robinson H. Mdegela

Bibliographic record

VenueInternational Journal of Chemistry · 2017
Typearticle
Languageen
FieldEnvironmental Science
TopicWater Quality Monitoring and Analysis
Canadian institutionsnot available
FundersDanish International Development AgencyUdenrigsministeriet
KeywordsChemistryChromatographyDetection limitEthinylestradiolBisphenol AEndocrine disruptorHigh-performance liquid chromatographyEndocrine systemHormonePopulation

Abstract

fetched live from OpenAlex

Endocrine disrupting estrogens are emerging contaminants in aquatic ecosystems and environment in general. There are no guidelines for routine monitoring of these chemicals, despite the existing evidences of their adverse health effect to living organisms at low concentrations. This study aimed at developing and validating an optimized HPLC-UV method for detection and quantification of estradiol and ethinylestradiol. Isocratic elution was used for separation and detection of ethinylestradiol and estradiol. The mobile phase was applied with A; water B; acetonitrile (50:50) at flow rate of 0.7mL/min and injection volume 10mL. The precision and accuracy of the method were within the acceptable range. Relative standard deviation of peak area for E2 ranged from 1.373 to 3.668%, and for EE2 ranged from 0.829 to 6.495 %. The percentage recovery for E2 ranged from 82.3 to 99.84 %, and for EE2 ranged from 84.6 to 103.52 %. Linearity of the method was realized at range of 2.5 to 50 ng/mL and 100 to 1000 ng/mL for both E2 and EE2. The linear regression coefficients were 0.9979 and 0.9973 for E2 whereas for EE2 were 0.9983 and 0.9976. Limit of detection were found to be 0.05 ng/mL and 0.08 ng/mL for E2 and EE2 respectively. The obtained limits of quantification were 0.18 and 0.28 ng/mL for E2 and EE2 respectively. In untreated sewage the concentrations of E2 and EE2 were 0.28 ng/ml and 0.18 ng/ml respectively. But in subsequent wastewater stabilization ponds the concentrations were below detection limit. Therefore, the optimized HPLC-UV method is suitable for detection and quantification of endocrine disrupting estrogens when a level of pollution is at least 0.15 ng/ml. At low extent of pollution would require use of the method in conjunction with ELISA technique.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.033
Threshold uncertainty score0.203

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.031
GPT teacher head0.388
Teacher spread0.357 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueInternational Journal of ChemistrySame topicWater Quality Monitoring and AnalysisFrench-language works237,207