MétaCan
Menu
Back to cohort
Record W2613852851 · doi:10.1021/acs.analchem.7b00280

Sensitive Detection of Glycated Albumin in Human Serum Albumin Using Electrochemiluminescence

2017· article· en· W2613852851 on OpenAlexaff
Yuki Inoue, Mikako Inoue, Masato Saito, Hiroyuki Yoshikawa, Eiichi Tamiya

Bibliographic record

VenueAnalytical Chemistry · 2017
Typearticle
Languageen
FieldEngineering
TopicElectrochemical sensors and biosensors
Canadian institutionsCanada Research ChairsUniversity of Toronto
FundersCore Research for Evolutional Science and TechnologyJapan Society for the Promotion of Science
KeywordsChemistrySalivaChromatographyAlbuminDetection limitBlood glucose monitoringHuman serum albuminDiabetes mellitusBiochemistryEndocrinologyMedicine

Abstract

fetched live from OpenAlex

Monitoring of blood glucose content is vital for diabetes patients. The conventional widely used method involves an invasive procedure for blood sampling. In addition, blood glucose measured by this way is affected by immediate food consumption and it does not show accurate baseline blood glucose measurement. Thus, monitoring blood glucose by a noninvasive method that accurately reflects baseline blood glucose content is important. Glycated albumin (GA), a biomarker for diabetes indicating the average blood glucose over 2 weeks, can be used for semilong-term blood glucose monitoring. Detection of GA in saliva is a noninvasive method that alleviates the use of needles for diabetic patients; however, its content in saliva is in the nanomolar range. Therefore, the GA enzymatic detection method was combined with the ECL method for a highly sensitive detection of GA in human serum albumin and in the saliva sample. Here, the standard curve was constructed using model substrate, FZK, between 0.1 and 2 μM, and GA in human serum albumin was measured in this range. Also, we successfully demonstrated the detection limit of 0.1 μM GA in human serum albumin sample using ECL, which has seen improvement of about 70 times more than the colorimetric methods. The detection of GA in real saliva sample suggested that sample dilution of 5 times may be necessary to suppress the ECL quenching effect by impurities.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.061
Threshold uncertainty score0.868

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.246
Teacher spread0.235 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations55
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueAnalytical ChemistrySame topicElectrochemical sensors and biosensorsFrench-language works237,207