MétaCan
Menu
Back to cohort
Record W2618627248 · doi:10.1089/dia.2017.0025

Factory-Calibrated Continuous Glucose Sensors: The Science Behind the Technology

2017· article· en· W2618627248 on OpenAlexaff
Udo Hoss, Erwin S. Budiman

Bibliographic record

VenueDiabetes Technology & Therapeutics · 2017
Typearticle
Languageen
FieldMedicine
TopicDiabetes Management and Research
Canadian institutionsAbbott (Canada)
Fundersnot available
KeywordsCalibrationFactory (object-oriented programming)Process (computing)Robustness (evolution)AutomationComputer scienceReal-time computingComputer hardwareAutomotive engineeringProcess engineeringEngineeringMechanical engineering

Abstract

fetched live from OpenAlex

The use of commercially available continuous glucose monitors for diabetes management requires sensor calibrations, which until recently are exclusively performed by the patient. A new development is the implementation of factory calibration for subcutaneous glucose sensors, which eliminates the need for user calibrations and the associated blood glucose tests. Factory calibration means that the calibration process is part of the sensor manufacturing process and performed under controlled laboratory conditions. The ability to move from a user calibration to factory calibration is based on several technical requirements related to sensor stability and the robustness of the sensor manufacturing process. The main advantages of factory calibration over the conventional user calibration are: (a) more convenience for the user, since no more fingersticks are required for calibration and (b) elimination of use errors related to the execution of the calibration process, which can lead to sensor inaccuracies. The FreeStyle Libre ™ and FreeStyle Libre Pro ™ flash continuous glucose monitoring systems are the first commercially available sensor systems using factory-calibrated sensors. For these sensor systems, no user calibrations are required throughout the sensor wear duration.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.010
metaresearch head score (Gemma)0.015
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: none
Teacher disagreement score0.010
Threshold uncertainty score0.051

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0100.015
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0020.001
Bibliometrics0.0020.003
Science and technology studies0.0010.005
Scholarly communication0.0060.008
Open science0.0030.003
Research integrity0.0050.007
Insufficient payload (model declined to judge)0.0030.003

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.030
GPT teacher head0.316
Teacher spread0.287 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations141
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueDiabetes Technology & TherapeuticsSame topicDiabetes Management and ResearchFrench-language works237,207