MétaCan
Menu
← Back to cohort
Record W2618684714 · doi:10.1111/cid.12504

Hybrid and fully‐etched surface implants in periodontally healthy patients: A comparative retrospective study on marginal bone loss

2017· article· en· W2618684714 on OpenAlexvenueno aff
Sergio Spinato, Fabio Bernardello, Paolo Sassatelli, Davide Zaffe

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2017
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsnot available
Fundersnot available
KeywordsDentistryMedicineMaxillaCoronal planeImplantPeri-implantitisProfilometerOrthodonticsMaterials scienceSurgeryComposite materialAnatomySurface roughness

Abstract

fetched live from OpenAlex

BACKGROUND: Human studies on implants with the same design but with different surfaces are lacking at the present time. PURPOSE: The aim of this study was to compare the survival rate of and marginal bone loss (MBL) around 2 types of implants with the same design, but with different surfaces: fully "sandblasted and double-etched" (SDE) implants and hybrid (H) implants, with an apical SDE-surface and a coronal machined-surface. MATERIALS AND METHODS: The SDE- and H-surfaces were previously analyzed under SEM and profilometer. Implants were placed in partially edentulous periodontally healthy patients requiring single implant-restoration, in either mandible or maxilla, with cement-retained prosthetic restoration. Twelve months after prosthetic loading, MBL in relation to prosthetic abutment height (AH), calculated radiographically, was statistically analyzed. RESULTS: SEM and profilometer analyses revealed no differences between the SDE-surfaces of either SDE- or H-implants. Transverse ridges and grooves characterized the machined portion of H-implants, clearly influencing the profilometer analysis. In 75 patients, 37 SDE and 38 H-implants were placed and all functioned completely after 12 months. In both SDE- and H-groups, MBL had a significant inverse relationship with AH, with greater intercept and negative slope for SDE-group and intersection of the 2 regression lines at AH = 2 mm. CONCLUSIONS: A 100% survival rate was recorded for SDE- and H-implants placed in pristine bone of periodontally healthy patients; MBL was limited and similar in both SDE- and H-groups; the higher the prosthetic AH, the lesser the MBL around implants; H-implants could reduce bone loss most effectively with abutments lower than 2 mm, realistically exploitable on thin biotypes; SDE-implants could reduce bone loss most effectively with abutments greater than 2 mm, realistically exploitable on thick biotypes.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.162
GPT teacher head0.499
Teacher spread0.336 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations15
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related Research→Same topicDental Implant Techniques and Outcomes→French-language works237,207→