Comparative Efficacy of Transfemoral Prosthetic Interfaces: Analysis of Gait and Perceived Disability

2017· article· en· W2619206935 on OpenAlexaboutno aff
Tyler D. Klenow, Jason T. Kahle, F. J. Fedel, Jeffrey Ropp, M. Jason Highsmith

Bibliographic record

VenueJPO Journal of Prosthetics and Orthotics · 2017
Typearticle
Languageen
FieldEngineering
TopicProsthetics and Rehabilitation Robotics
Canadian institutionsnot available
Fundersnot available
KeywordsGaitPhysical medicine and rehabilitationAmputationPhysical therapyGait analysisForce platformMedicineProsthesisComputer sciencePsychologySurgery

Abstract

fetched live from OpenAlex

ABSTRACT Introduction The High-Fidelity (HiFi) interface is an emerging transfemoral interface technology. However, no comparison of this interface to traditional transfemoral interface designs is currently available. The purpose of this study is to measure the effects of the HiFi system on gait and perceived disability compared with a traditional socket design in a subject with transfemoral amputation. Methods The subject was first tested with a traditional ischial containment socket, then fit with the HiFi system, and tested again after a 30-day accommodation period. Three-dimensional motion analysis was performed using an 8-camera Vicon Motion Capture system. The Oswestry Low Back Pain Disability Questionnaire v2.0 and Western Ontario and McMaster University Osteoarthritis index were administered at initial and secondary testing to evaluate perceived disability. A one-way analysis of variance and Fischer's least significant difference were used to determine statistical difference between conditions. The level of significance for all tests was set at P ≤ 0.05. Results Notable results included an increase in self-selected gait velocity, prosthetic hip adduction, and hip extension. Reductions in lateral center of mass deviation during gait and in perceived disability was also shown with use of the HiFi condition. Discussion This study analyzed the effects of the HiFi Interface System on biomechanical parameters of gait and perceived disability compared with a baseline IRC condition in this elderly subject with history of TF amputation. Several improvements and markers of increased stability with use of the HiFi were noted. Perceived disability was also greatly improved comparatively. Conclusions The HiFi Interface System presented some biomechanical advantages to traditional IRC socket designs in this case, which may allow for increased stability in patients utilizing a TF prosthesis. Further research with larger samples is warranted.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.022
GPT teacher head0.284
Teacher spread0.262 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueJPO Journal of Prosthetics and OrthoticsSame topicProsthetics and Rehabilitation RoboticsFrench-language works237,207