MétaCan
Menu
Back to cohort
Record W2622267309 · doi:10.5897/jmer.9000038

Performance of a water ammonia absorption system operating at three pressure levels

2011· article· en· W2622267309 on OpenAlexvenueno aff
Nahla Bouaziz, Ridha Ben Iffa, Lakdar Kairouani

Bibliographic record

VenueMechanical Engineering Research · 2011
Typearticle
Languageen
FieldEngineering
TopicRefrigeration and Air Conditioning Technologies
Canadian institutionsnot available
Fundersnot available
KeywordsEvaporatorCondenser (optics)RefrigerationAbsorption refrigeratorMechanical engineeringWorking fluidAmmoniaGenerator (circuit theory)Work (physics)Materials scienceNuclear engineeringComputer scienceThermodynamicsProcess engineeringAutomotive engineeringChemistryEngineeringPhysicsHeat exchangerPower (physics)Optics

Abstract

fetched live from OpenAlex

The present study deals with a compression-absorption machine. The proposed hybrid cooling system uses water-ammonia as a working fluid and operates at three pressure levels. The absorber is at an intermediate pressure (Pint) taken between the evaporator pressure (PEV) and the condenser pressure (PCD), unlike the single stage machine, which works between two pressure levels. The proposed new system is studied and compared to the conventional machine. In order to evaluate the performance of the invoked system, a procedure based on the MAPLE software is set up to compute accurately the thermodynamic properties of the working fluid. The analyses of the numerical results highlight that the performance of the novel proposed configuration is better than that relative to the conventional cycle. The study reveals the great impact of the intermediate pressure on the performance improvement and on reducing the generator temperature allowing the system to work at low enthalpy sources. In fact, for an evaporator temperature and a condenser temperature fixed respectively at -10 and 40°C, the proposed hybrid refrigeration cycle operates at a generator temperature TGE = 75°C and the installation’s COP is about 0.56. While for the same conditions, the single stage machine COP cannot exceed 0.51 with a generator temperature of about 100°C.   Key words: Absorption, ammonia, COP, hybrid, refrigeration.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.065
GPT teacher head0.258
Teacher spread0.193 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations13
Published2011
Admission routes1
Has abstractyes

Explore more

Same venueMechanical Engineering ResearchSame topicRefrigeration and Air Conditioning TechnologiesFrench-language works237,207