MétaCan
Menu
Back to cohort
Record W2626940778 · doi:10.1002/mp.12407

Technical Note: Comparison of megavoltage, dual‐energy, and single‐energy CT‐based μ‐maps for a four‐channel breast coil in PET/MRI

2017· article· en· W2626940778 on OpenAlexafffund
John Patrick, Robert T. Thompson, Aaron So, John Butler, David Faul, Robert Z. Stodilka, Slav Yartsev, Frank S. Prato, Stewart Gaede

Bibliographic record

VenueMedical Physics · 2017
Typearticle
Languageen
FieldEngineering
TopicAdvanced X-ray and CT Imaging
Canadian institutionsRobarts Clinical TrialsLawson Health Research InstituteCancer Care OntarioWestern University
FundersSiemens Canada
KeywordsImaging phantomElectromagnetic coilNuclear medicineRadiofrequency coilBreast imagingAttenuationCorrection for attenuationArtifact (error)Monochromatic colorPhysicsOpticsMedicineComputer scienceMammographyBreast cancerArtificial intelligence

Abstract

fetched live from OpenAlex

PURPOSE: The purpose of this study was to describe and evaluate methods for calculating a megavoltage computed tomography (MVCT)-derived MR hardware attenuation map (μ-map) and dual-energy CT (DECT) for 511 keV photons. METHODS: Phantom measurements were acquired on a whole-body hybrid PET/MRI system, using a four-channel receive-only MR radiofrequency (RF) breast coil. Two acquisitions were performed: with the phantoms positioned in the four-channel RF breast coil, and without the breast coil. PET attenuation from the breast coil was corrected using three different CT-derived hardware μ-maps: (a) Single-energy CT (SECT), (b) DECT, and (c) MVCT. Each attenuation-corrected (AC) PET volume was evaluated and compared with the acquisition performed without the breast coil. RESULTS: The breast coil attenuated PET photons by 10% overall. Threshold values were applied to the SECT μ-map to reduce the effects of metal artifacts, but overcorrection occurred in more highly attenuated regions. The DECT-derived virtual monochromatic image reduced beam-hardening artifacts, but other metal artifacts remained. Despite the remaining metal artifacts in the DECT image, it led to an improvement in the more attenuated regions. The MVCT images appear to be free from metal artifacts leading to an artifact-free μ-map and a further improvement AC-PET images. CONCLUSIONS: Our MVCT-based approach for creating μ-maps for MR RF coils greatly reduces artifacts produced by metal in a SECT approach. This eliminates the need for other artifact reduction methods, including the application of a threshold of narrow beam attenuation coefficients, or disassembling hardware to remove high-Z components before imaging with a kilovoltage source.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.010
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.003
Threshold uncertainty score0.018

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.010
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.273
Teacher spread0.254 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations13
Published2017
Admission routes2
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced X-ray and CT ImagingFrench-language works237,207