MétaCan
Menu
Back to cohort
Record W2673918298 · doi:10.1111/aos.13464

Intra‐ and interobserver reproducibility of Bruch's membrane opening minimum rim width measurements with spectral domain optical coherence tomography

2017· article· en· W2673918298 on OpenAlexaff
Alexandre Soares Castro Reis, Camila e Silva Zangalli, Ricardo Y. Abe, André Leandro Silva, Jayme R Vianna, José Paulo Cabral de Vasconcellos, Vital Paulino Costa

Bibliographic record

VenueActa Ophthalmologica · 2017
Typearticle
Languageen
FieldMedicine
TopicGlaucoma and retinal disorders
Canadian institutionsDalhousie University
FundersConselho Nacional de Desenvolvimento Científico e Tecnológico
KeywordsReproducibilityBruch's membraneOptical coherence tomographyGlaucomaStandard deviationOphthalmologyRetinalSpearman's rank correlation coefficientMedicineRank correlationNuclear medicineMathematicsStatistics

Abstract

fetched live from OpenAlex

PURPOSE: To investigate the reproducibility of Bruch's membrane opening minimum rim width (BMO-MRW) and retinal nerve fibre layer thickness (RNFLT) measurements using spectral domain optical coherence tomography (SD-OCT). Additionally, to investigate the reproducibility of BMO area measurements and fovea to BMO centre (FoBMO) angle. METHODS: Participants were healthy subjects (n = 30) and patients with glaucoma (n = 26). One eye of each participant was scanned to obtain optic nerve head (24 radial B-scans) and peripapillary (one circular B-scan) images by three independent examiners. Additionally, one examiner imaged each participant three times on the same day. Intra- and interobserver reproducibilities were estimated by within-subject standard deviation (SW) and coefficient of variation (COV). Spearman's rank correlation coefficient was used to test the correlation between the magnitude of the parameter and its standard deviation. RESULTS: The global BMO-MRW COVs (%) in healthy/glaucoma subjects were 0.87/1.34 and 1.28/3.13 for intra- and interobserver analyses, respectively, and the corresponding global RNFLT figures were 1.50/2.10 and 2.04/2.87. Global mean BMO-MRW and RNFLT showed no correlation with their respective standard deviations. The reproducibilities of BMO area and FoBMO angle were excellent and similar between the groups. CONCLUSION: The reproducibilities of BMO-MRW, BMO area measurements and FoBMO angle were excellent in both healthy subjects and patients with glaucoma. Bruch's membrane opening minimum rim width (BMO-MRW) reproducibility is comparable to that of RNFLT measurements.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.069
Threshold uncertainty score0.646

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.053
GPT teacher head0.300
Teacher spread0.246 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations30
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueActa OphthalmologicaSame topicGlaucoma and retinal disordersFrench-language works237,207