MétaCan
Menu
Back to cohort
Record W2732828647 · doi:10.5114/jcb.2017.68467

Is intraoperative real-time dosimetry in prostate seed brachytherapy predictive of biochemical outcome?

2017· article· en· W2732828647 on OpenAlexaff
Daniel Taussky, Levon Igidbashian, David Donath, Dominic Béliveau-Nadeauv, Renée Larouche, Yanick Hervieux, Guila Delouya

Bibliographic record

VenueJournal of Contemporary Brachytherapy · 2017
Typearticle
Languageen
FieldMedicine
TopicProstate Cancer Diagnosis and Treatment
Canadian institutionsCentre Hospitalier de l’Université de MontréalCentre Integre de Sante et de Services Sociaux de LavalUniversité de MontréalHôpital Notre-Dame
Fundersnot available
KeywordsDosimetryMedicineBrachytherapyNuclear medicineInterquartile rangeProstate brachytherapyImplantRadiation therapyRadiologySurgery

Abstract

fetched live from OpenAlex

Purpose: To analyze intraoperative (IO) dosimetry using transrectal ultrasound (TRUS), performed before and after prostate low-dose-rate brachytherapy (LDR-BT), and compare it to dosimetry performed 30 days following the LDR-BT implant (Day 30). Material and methods:A total of 236 patients underwent prostate LDR-BT using 125 I that was performed with a three-dimensional TRUS-guided interactive inverse preplanning system (preimplant dosimetry).After the implant procedure, the TRUS was repeated in the operating room, and the dosimetry was recalculated (postimplant dosimetry) and compared to dosimetry on Day 30 computed tomography (CT) scans.Area under curve (AUC) statistics was used for models predictive of dosimetric parameters at Day 30.Results: The median follow-up for patients without BF was 96 months, the 5-year and 8-year biochemical recurrence (BR)-free rate was 96% and 90%, respectively.The postimplant median D 90 was 3.8 Gy lower (interquartile range [IQR], 12.4-0.9),and the V 100 only 1% less (IQR, 2.9-0.2%)than the preimplant dosimetry.When comparing the postimplant and the Day 30 dosimetries, the postimplant median D 90 was 9.6 Gy higher (IQR [-] 9.5-30.3Gy), and the V 100 was 3.2% greater (0.2-8.9%) than Day 30 postimplant dosimetry.The variables that best predicted the D 90 of Day 30 was the postimplant D 90 (AUC = 0.62, p = 0.038).None of the analyzed values for IO or Day 30 dosimetry showed any predictive value for BR. Conclusions:Although improving the IO preimplant and postimplant dosimetry improved dosimetry on Day 30, the BR-free rate was not dependent on any dosimetric parameter.Unpredictable factors such as intraprostatic seed migration and IO factors, prevented the accurate prediction of Day 30 dosimetry.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.006
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.006
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.031
GPT teacher head0.336
Teacher spread0.305 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations7
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Contemporary BrachytherapySame topicProstate Cancer Diagnosis and TreatmentFrench-language works237,207