MétaCan
Menu
Back to cohort
Record W2739186614 · doi:10.1002/mp.12459

A generic TG‐186 shielded applicator for commissioning model‐based dose calculation algorithms for high‐dose‐rate <sup>192</sup>Ir brachytherapy

2017· article· en· W2739186614 on OpenAlexafffund
Yunzhi Ma, J. Vijande, Facundo Ballester, Åsa Carlsson Tedgren, Domingo Granero, Annette Haworth, Firas Mourtada, Gabriel Paiva Fonseca, K. Zourari, Panagiotis Papagiannis, Mark J. Rivard, Frank‐André Siebert, Ron S. Sloboda, Ryan Smith, Marc Chamberland, Rowan M. Thomson, Frank Verhaegen, Luc Beaulieu

Bibliographic record

VenueMedical Physics · 2017
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsCarleton UniversityUniversity of AlbertaUniversité Laval
FundersNatural Sciences and Engineering Research Council of CanadaBarncancerfondenGeneralitat ValencianaSwedish Cancer Foundation
KeywordsBrachytherapyImaging phantomDosimetryShielded cableRadiation treatment planningTask groupNuclear medicineMonte Carlo methodMedical physicsComputer sciencePhysicsRadiation therapyMathematicsMedicineEngineeringRadiologyStatistics

Abstract

fetched live from OpenAlex

Purpose A joint working group was created by the American Association of Physicists in Medicine (AAPM), the European Society for Radiotherapy and Oncology (ESTRO), and the Australasian Brachytherapy Group (ABG) with the charge, among others, to develop a set of well‐defined test case plans and perform calculations and comparisons with model‐based dose calculation algorithms (MBDCAs). Its main goal is to facilitate a smooth transition from the AAPM Task Group No. 43 (TG‐43) dose calculation formalism, widely being used in clinical practice for brachytherapy, to the one proposed by Task Group No. 186 (TG‐186) for MBDCAs. To do so, in this work a hypothetical, generic high‐dose rate (HDR) 192Ir shielded applicator has been designed and benchmarked. Methods A generic HDR 192Ir shielded applicator was designed based on three commercially available gynecological applicators as well as a virtual cubic water phantom that can be imported into any DICOM‐RT compatible treatment planning system (TPS). The absorbed dose distribution around the applicator with the TG‐186 192Ir source located at one dwell position at its center was computed using two commercial TPSs incorporating MBDCAs (Oncentra® Brachy with Advanced Collapsed‐cone Engine, ACE™, and BrachyVision ACUROS™) and state‐of‐the‐art Monte Carlo (MC) codes, including ALGEBRA, BrachyDose, egs_brachy, Geant4, MCNP6, and Penelope2008. TPS‐based volumetric dose distributions for the previously reported “source centered in water” and “source displaced” test cases, and the new “source centered in applicator” test case, were analyzed here using the MCNP6 dose distribution as a reference. Volumetric dose comparisons of TPS results against results for the other MC codes were also performed. Distributions of local and global dose difference ratios are reported. Results The local dose differences among MC codes are comparable to the statistical uncertainties of the reference datasets for the “source centered in water” and “source displaced” test cases and for the clinically relevant part of the unshielded volume in the “source centered in applicator” case. Larger local differences appear in the shielded volume or at large distances. Considering clinically relevant regions, global dose differences are smaller than the local ones. The most disadvantageous case for the MBDCAs is the one including the shielded applicator. In this case, ACUROS agrees with MC within [−4.2%, +4.2%] for the majority of voxels (95%) while presenting dose differences within [−0.12%, +0.12%] of the dose at a clinically relevant reference point. For ACE, 95% of the total volume presents differences with respect to MC in the range [−1.7%, +0.4%] of the dose at the reference point. Conclusions The combination of the generic source and generic shielded applicator, together with the previously developed test cases and reference datasets (available in the Brachytherapy Source Registry), lay a solid foundation in supporting uniform commissioning procedures and direct comparisons among treatment planning systems for HDR 192Ir brachytherapy.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.003
Threshold uncertainty score0.011

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.030
GPT teacher head0.332
Teacher spread0.302 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations50
Published2017
Admission routes2
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207