Detection of Plasmodium Infection by the illumigene Malaria Assay Compared to Reference Microscopy and Real-Time PCR

2017· article· en· W2740736991 on OpenAlexafffund
Candace Rypien, Barbara L. Chow, Wilson Chan, Deirdre L. Church, Dylan R. Pillai

Bibliographic record

VenueJournal of Clinical Microbiology · 2017
Typearticle
Languageen
FieldMedicine
TopicMalaria Research and Control
Canadian institutionsCalgary Laboratory ServicesUniversity of Calgary
FundersCalgary Laboratory Services
KeywordsMalariaLoop-mediated isothermal amplificationGiemsa stainBlood smearMedicineDiagnosis of malariaVirologyConfidence intervalBiologyImmunologyInternal medicinePathologyPlasmodium falciparum

Abstract

fetched live from OpenAlex

ABSTRACT Malaria is one of the leading causes of infectious disease in travelers returning from the tropics. The diagnosis of malaria is typically performed by examining Giemsa-stained thick and thin peripheral blood smears, which is time consuming, labor intensive, and requires high levels of proficiency. Alternatively, loop-mediated isothermal amplification (LAMP) is a new molecular method, which is rapid, sensitive, and requires less capital equipment and technological training. We conducted a retrospective study comparing two formats of a commercial LAMP assay (Meridian illumi gene malaria [M] and malaria Plus [MP]) versus reference microscopy on archived blood specimens ( n = 140) obtained from unique returning travelers suspected of having malaria. Discrepant results were resolved by either repeat testing or a laboratory developed ultrasensitive real-time PCR method. On initial testing, the Meridian illumi gene M and MP kits had sensitivities of 97.3% (95% confidence interval [CI], 90.7 to 99.7%) and 100.0% (95.1 to 100.0%) and specificities of 93.8% (84.8 to 98.3%) and 91.5% (81.3 to 97.2%), respectively, versus reference microscopy. We project a significant cost reduction in low prevalence settings where malaria is not endemic with LAMP-based malaria screening given the excellent negative predictive value achieved with LAMP.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.003
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.791
Threshold uncertainty score0.375

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0030.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.051
GPT teacher head0.390
Teacher spread0.339 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations61
Published2017
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Clinical MicrobiologySame topicMalaria Research and ControlFrench-language works237,207