MétaCan
Menu
Back to cohort
Record W2742436675 · doi:10.1371/journal.pone.0182632

A randomized multicenter trial comparing the XIENCE everolimus eluting stent with the CYPHER sirolimus eluting stent in the treatment of female patients with de novo coronary artery lesions: The SPIRIT WOMEN study

2017· article· en· W2742436675 on OpenAlexaff
Anna Franzone, Serge Zaugg, Raffaele Piccolo, Maria Grazia Modena, Ghada Mikhail, Josepa Mauri Ferré, Ruth H. Strasser, Liliana Grinfeld, Dik Heg, Peter Jüni, Stephan Windecker, Marie‐Claude Morice

Bibliographic record

VenuePLoS ONE · 2017
Typearticle
Languageen
FieldMedicine
TopicCoronary Interventions and Diagnostics
Canadian institutionsUniversity of TorontoSt. Michael's Hospital
FundersAbbott VascularCardiovascular SystemsMedicines CompanyBoston Scientific CorporationSt. Jude MedicalBiosensors International GroupEli Lilly and Company
KeywordsMedicineStentPercutaneous coronary interventionRestenosisDrug-eluting stentInternal medicineStenosisSirolimusEverolimusMyocardial infarctionCardiologyRandomized controlled trialConventional PCICoronary artery diseaseSurgery

Abstract

fetched live from OpenAlex

BACKGROUND: The comparative performance of different drug-eluting stents (DES) among female patients has not been assessed in a randomized manner. OBJECTIVES: The SPIRIT Women Clinical Evaluation trial compared the durable polymer everolimus-eluting XIENCE stent (DP-EES) with the durable polymer sirolimus-eluting Cypher stent (DP-SES) in women undergoing percutaneous coronary intervention (PCI). METHODS: A total of 455 female patients with stable CAD were randomly assigned to receive DP-EES (n = 304) or DP-SES (n = 151). The powered angiographic outcome of the trial was in-stent late lumen loss (LLL) at 9 months after the index procedure. Secondary angiographic end points included in-segment LLL, in-stent and in-segment binary restenosis and percent diameter stenosis. The primary clinical outcome was a composite of all-cause death, myocardial infarction (MI) or target vessel revascularization (TVR). RESULTS: At 9-month follow-up, in-stent LLL was 0.19±0.38 mm and 0.11±0.37 mm in patients assigned to DP-EES and DP-SES, respectively. The one-sided upper 95% CI of the difference in in-stent LLL between the groups of 0.08 mm was 0.15 and therefore within the pre-specified non-inferiority margin of 0.17 mm (p for non-inferiority = 0.013). However, the test for superiority showed a borderline significant difference in terms of LLL between DP-EES and DP-SES (p for superiority = 0.044). There were no significant differences in binary restenosis (2.0% vs. 0.72%, p = 0.44) and percent diameter stenosis (14.97±12.17 vs. 13.36±10.82, p = 0.19). The rate of definite stent thrombosis at 12 months was lower in patients treated with DP-EES (0% vs. 2.0%, p = 0.036). CONCLUSIONS: Among women undergoing PCI, DP-EES was associated with a small but probably clinically relevant increase in in-stent LLL at 9 months as compared to DP-SES and with a lower risk of definite stent thrombosis at 12 months. TRIAL REGISTRATION: ClinicalTrials.gov NCT01182428. https://clinicaltrials.gov/.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.152
Threshold uncertainty score0.582

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0010.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.081
GPT teacher head0.293
Teacher spread0.212 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations16
Published2017
Admission routes1
Has abstractyes

Explore more

Same venuePLoS ONESame topicCoronary Interventions and DiagnosticsFrench-language works237,207