MétaCan
Menu
Back to cohort
Record W2751451059 · doi:10.1017/s1460396917000176

Preclinical studies for implementing flattening filter-free beams in hypofractionated volumetric-modulated arc therapy (VMAT) for prostate cancer radiotherapy

2017· article· en· W2751451059 on OpenAlexaff
Баочанг Лиу, Johnson Darko, Ernest Osei

Bibliographic record

VenueJournal of Radiotherapy in Practice · 2017
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsUniversity of GuelphGrand River HospitalUniversity of WaterlooBC Cancer Agency
FundersAccuraySun Nuclear Corporation
KeywordsTruebeamRadiation therapyNuclear medicineMedicineProstate cancerRadiation treatment planningProstateMedical physicsCancerLinear particle acceleratorRadiologyBeam (structure)Internal medicineOpticsPhysics

Abstract

fetched live from OpenAlex

Abstract Background Volumetric-modulated arc therapy (VMAT) has emerged as one of the most favourable techniques for radiotherapy treatment in recent years because of its conformal dose distribution to the planning target volume (PTV), lower doses to adjacent normal organs at risk (OARs) and faster and easier dose delivery. A typical conventional VMAT protocol for low-intermediate risk prostate cancer uses a flattened 6 MV photon beam to deliver 78 Gy in 39 fractions, however, a recent Radiation Therapy Oncology Group study investigated prostate cancer radiotherapy with a hypofractionated dose scheme of 36·25 Gy in 5 fractions. One advantage of flattening filter-free (FFF) beams in radiotherapy is the higher doses in the central region on the dose profile and much higher dose delivery rates. Methods and materials This paper reports the investigation of preclinical studies for implementing FFF beams in hypofractionated VMAT for prostate cancer radiotherapy. All treatment planning were accomplished using Varian Eclipse TM treatment planning system version 11 and delivered on Varian Truebeam linear accelerators. The studies compared the biological-effective dose–volume histograms and dose–volume histograms of PTV and OARs for 20 patients using conventional and hypofractionated dose schemes. The study also evaluated the 6 and 10 MV FFF by comparing 6 and 10 MV VMAT plans with the FFF beams. The treatment time was investigated using plans with 6 MV beams and doses of 2, 4, 5, 6, 7·25 Gy/fraction and plans with 10 MV FFF with a dose of 7·25 Gy/fraction. We also investigated an angular monitor unit (MU) quantity (MU/deg) and its threshold value for RapidArc TM plans, beyond which FFF beams can be considered superior to flattened beams in terms of treatment time increased caused by higher dose per fraction. Results The results show that the hypofractionated plans resulted in greater biological equivalent doses to PTV and lower doses to OARs. The 10 MV FFF plans have statistically lower mean doses to all the OARs, whereas PTV homogeneity index remains the same compared with other beam energies. The mean body integral dose for the 20 patients is 8·7% lower using 10 MV FFF compared with 6 MV FFF mainly because of the higher energy and less required MUs with the 10 MV FFF beam. The hypofractionated scheme with 10 MV FFF plan has the same treatment time as that of the 6 MV plan at 2 Gy/fraction, as the higher dose delivery rates at 10 MV FFF can compensate for the higher prescribed dose per fraction without the need of extra treatment time. Conclusion In this study, we observed that the 10 MV FFF beam is better for hypofractionated prostate cancer VMAT plan delivery. The threshold value of MU/deg is found to be 2·083 MU/deg based on our machine configurations.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.848
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0030.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.000
Science and technology studies0.0010.000
Scholarly communication0.0000.003
Open science0.0010.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.060
GPT teacher head0.440
Teacher spread0.381 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designNot applicable
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Radiotherapy in PracticeSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207