Initial Clinical Experience With a New Automated Antitachycardia Pacing Algorithm

2017· article· en· W2751530646 on OpenAlexaff
Raymond Yee, John D. Fisher, Ulrika Birgersdotter‐Green, Timothy W. Smith, David N. Kenigsberg, Robert C. Canby, Troy Jackson, Robert T. Taepke, Paul DeGroot

Bibliographic record

VenueCirculation Arrhythmia and Electrophysiology · 2017
Typearticle
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsWestern University
Fundersnot available
KeywordsMedicineCardiologyInternal medicineVentricular tachycardiaImplantable cardioverter-defibrillatorVentricular fibrillationSupraventricular tachycardiaEjection fractionAtrial fibrillationSupraventricular arrhythmiaAmbulatoryShock (circulatory)DefibrillationAlgorithmTachycardiaHeart failure

Abstract

fetched live from OpenAlex

BACKGROUND: Antitachycardia pacing (ATP) in implantable cardioverter-defibrillators (ICD) decreases patient shock burden but has recognized limitations. A new automated ATP (AATP) based on electrophysiological first principles was designed. The study objective was to assess the feasibility and safety of AATP in ambulatory ICD patients. METHODS AND RESULTS: Enrolled patients had dual chamber or cardiac resynchronization therapy ICDs, history of ≥1 ICD-treated ventricular tachycardias (VT)/ventricular fibrillation episode, or a recorded, sustained monomorphic VT. Detection was set to ventricular fibrillation number of intervals to detect=24/32, VT number of intervals to detect≥16, and a fast VT zone of 240 to 320 ms. AATP prescribed the components and delivery of successive ATP sequences in real time, using the same settings for all patients. ICD datalogs were uploaded every ≈3 months, at unscheduled visits, exit, and death. Episodes and adverse events were adjudicated by separate committees. Results were adjusted (generalized estimating equations) for multiple episodes. AATP was downloaded into the ICDs of 144 patients (121 men), aged 67.4±11.9 years, left ventricular ejection fraction 33.1±13.6% (n=137), and treated 1626 episodes in 49 patients during 14.5±5.1 months of follow-up. Datalogs permitted adjudication of 702 episodes, including 669 sustained monomorphic VT, 20 polymorphic VT, 10 supraventricular tachycardia, and 3 malsensing episodes. AATP terminated 39 of 69 (59% adjusted) sustained monomorphic VT in the fast VT zone, 509 of 590 (85% adjusted) in the VT zone, and 6 of 10 in the ventricular fibrillation zone. No supraventricular tachycardias converted to VT or ventricular fibrillation. No anomalous AATP behavior was observed. CONCLUSIONS: The new AATP algorithm safely generated ATP sequences and controlled therapy progression in all zones without need for individualized programing.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.422
Threshold uncertainty score0.491

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.038
GPT teacher head0.381
Teacher spread0.343 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations34
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueCirculation Arrhythmia and ElectrophysiologySame topicCardiac pacing and defibrillation studiesFrench-language works237,207