MétaCan
Menu
Back to cohort
Record W2752590382 · doi:10.1111/1471-0528.14760

Pressure and traction on a model fetal head and neck associated with the use of forceps, Kiwi™ ventouse and the BD Odon Device™ in operative vaginal birth: a simulation study

2017· article· en· W2752590382 on OpenAlexfundno aff
Stephen O’Brien, Cathy Winter, Christy Burden, Michel Boulvain, TJ Draycott, Joanna F. Crofts

Bibliographic record

VenueBJOG An International Journal of Obstetrics & Gynaecology · 2017
Typearticle
Languageen
FieldMedicine
TopicMaternal and Perinatal Health Interventions
Canadian institutionsnot available
FundersGrand Challenges CanadaKorea International Cooperation AgencyBDNational Institute for Health and Care ResearchGovernment of the United KingdomBill and Melinda Gates FoundationUnited States Agency for International Development
KeywordsForcepsTraction (geology)Head and neckSurgeryMedicineBiology

Abstract

fetched live from OpenAlex

OBJECTIVE: To determine the pressure and traction forces exerted on a model fetal head by the BD Odon Device, forceps and Kiwi ventouse during simulated births. DESIGN: Simulation study. SETTING: Simulated operative vaginal birth. POPULATION OR SAMPLE: Eighty-four simulated operative vaginal births. METHODS: A bespoke fetal mannequin with pressure sensors around the head and strain gauge across the neck was used to investigate pressure applied over the head, and traction across the neck during 84 simulated births using the BD Odon Device, non-rotational forceps and Kiwi ventouse. MAIN OUTCOME MEASURES: Peak pressure on the fetal face and lateral aspects of the head during correct use of the BD Odon Device and forceps. Peak pressure on orbits and neck during misplacement of the BD Odon Device and forceps. Peak traction force generated until instrument failure using the BD Odon Device, forceps and Kiwi ventouse. RESULTS: When correctly sited and using 80 kPa inflation pressure on the cuff, the BD Odon Device generated a lower peak pressure on the fetal head than forceps (83 versus 146 kPa). When instruments were purposefully misplaced over the orbits, the BD Odon Device generated a lower peak pressure on the orbits compared with forceps (70 versus 123 kPa). When purposefully misplaced over the neck, the BD Odon Device, compared with forceps, generated a greater peak pressure on the anterio-lateral aspect of the neck (56 versus 17 kPa) and a lower peak pressure on the posterior aspect of the neck (76 versus 93 kPa) than forceps. In cases of true cephalic disproportion, the BD Odon Device 'popped-off' at a lower traction force than did forceps (208 versus 270 N). CONCLUSIONS: In simulated assisted vaginal birth with correctly placed instruments, the peak pressure exerted on the fetal head by a BD Odon Device is lower than the pressure exerted by non-rotational forceps. In cases in which delivery of the fetal head is not possible due to cephalo-pelvic disproportion, lower traction forces could be applied using the BD Odon Device than with forceps before the procedure was abandoned due to device failure. TWEETABLE ABSTRACT: BD Odon Device exerts less pressure on a model fetal head than forceps, but more than Kiwi ventouse.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.117
Threshold uncertainty score0.235

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.104
GPT teacher head0.401
Teacher spread0.297 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations28
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueBJOG An International Journal of Obstetrics & GynaecologySame topicMaternal and Perinatal Health InterventionsFrench-language works237,207