MétaCan
Menu
Back to cohort
Record W2752700222 · doi:10.1088/1361-6579/aa8b59

Theoretical and experimental comparison of lag-based and time-based exponential moving average models of QT hysteresis

2017· article· en· W2752700222 on OpenAlexafffund
Vincent Jacquemet, Hugo Gravel, Daniel Curnier, Alain Vinet

Bibliographic record

VenuePhysiological Measurement · 2017
Typearticle
Languageen
FieldMedicine
TopicCardiac electrophysiology and arrhythmias
Canadian institutionsCentre Hospitalier Universitaire Sainte-JustineUniversité de MontréalHôpital du Sacré-Cœur de Montréal
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsMathematicsTime constantImpulse (physics)Moving averageAutoregressive modelControl theory (sociology)Exponential functionImpulse responseHysteresisExponential growthStatisticsComputer scienceMathematical analysisPhysicsEngineeringArtificial intelligence

Abstract

fetched live from OpenAlex

OBJECTIVE: In the electrocardiogram, adaptation of the QT interval to variations in heart rate is not instantaneous. Quantification of this hysteresis phenomenon relies on mathematical models describing the relation between the RR and QT time series. These models reproduce hysteresis through an effective RR interval computed as a linear combination of the history of past RR intervals. This filter depends on a time constant parameter that may be used as a biomarker. APPROACH: The most common hysteresis model is based on an autoregressive filter with an impulse response that decreases exponentially with the beat number (lag-based model). Recognizing that the QT time series is unevenly spaced, we propose two exponential moving average filters (time-based models) to define the effective RR interval: one with an impulse response that decreases exponentially with time in seconds, and one with a step response that relaxes exponentially with time in seconds. These two filters are neither linear nor time-invariant. Recurrence formulas are derived to enable efficient implementation. MAIN RESULTS: Application to clinical signals recorded during tilt table test, exercise and 24 h Holter demonstrates that the three models perform similarly in terms of goodness-of-fit. When comparing the hysteresis time constant in two conditions with different heart rates, however, the time-based models are shown to reduce the bias on the hysteresis time constant caused by heart rate acceleration and deceleration. SIGNIFICANCE: Time-based models should be considered when intergroup differences in both heart rate and QT hysteresis are expected.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.095
Threshold uncertainty score0.507

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.059
GPT teacher head0.305
Teacher spread0.246 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2017
Admission routes2
Has abstractyes

Explore more

Same venuePhysiological MeasurementSame topicCardiac electrophysiology and arrhythmiasFrench-language works237,207