MétaCan
Menu
Back to cohort
Record W2754715013 · doi:10.1002/acm2.12182

Magnetic field dose effects on different radiation beam geometries for hypofractionated partial breast irradiation

2017· article· en· W2754715013 on OpenAlexaff
Anthony D. Kim, Stephanie Lim‐Reinders, Claire McCann, S Ahmad, Arjun Sahgal, Justin Lee, Brian Keller

Bibliographic record

VenueJournal of Applied Clinical Medical Physics · 2017
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsHealth Sciences CentreUniversity of TorontoSunnybrook Health Science Centre
FundersElekta
KeywordsNuclear medicineRadiation treatment planningIrradiationDosimetryRadiation therapyMedicineLinear particle acceleratorBeam (structure)RadiologyPhysicsOptics

Abstract

fetched live from OpenAlex

PURPOSE: Hypofractionated partial breast irradiation (HPBI) involves treatment to the breast tumor using high doses per fraction. Recent advances in MRI-Linac solutions have potential in being applied to HPBI due to gains in the soft tissue contrast of MRI; however, there are potentially deleterious effects of the magnetic field on the dose distribution. The purpose of this work is to determine the effects of the magnetic field on the dose distribution for HPBI tumors using a tangential beam arrangement (TAN), 5-beam intensity-modulated radiation therapy (IMRT), and volumetric modulated arc therapy (VMAT). METHODS: Five patients who have received HPBI were selected with two patients having bilateral disease resulting in a total of two tumors in this study. Six planning configurations were created using a treatment planning system capable of modeling magnetic field dose effects: TAN, IMRT and VMAT beam geometries, each of these optimized with and without a transverse magnetic field of 1.5 T. RESULTS: The heart and lung doses were not statistically significant when comparing plan configurations. The magnetic field had a demonstrated effect on skin dose: for VMAT plans, the skin (defined to a depth of 3 mm) D1cc was elevated by +11% and the V30 by +146%; for IMRT plans, the skin D1cc was increased by +18% and the V30 by +149%. Increasing the number of beam angles (e.g., going from IMRT to VMAT) with the magnetic field on reduced the skin dose. CONCLUSION: The impact of a magnetic field on HPBI dose distributions was analyzed. The heart and lung doses had clinically negligible effects caused by the magnetic field. The magnetic field increases the skin dose; however, this can be mitigated by increasing the number of beam angles.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.982
Threshold uncertainty score0.582

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.017
GPT teacher head0.353
Teacher spread0.336 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations25
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Applied Clinical Medical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207