MétaCan
Menu
Back to cohort
Record W2757324605 · doi:10.5539/ijc.v9n4p49

Extraction-Spectrophotometric Determination of Lidocaine Hydrochloride in Pharmaceuticals

2017· article· en· W2757324605 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

venuePublished in a venue whose home country is Canada.
no affNo Canadian affiliation: this work is invisible to an affiliation-only frame.
No Canadian affiliation. An affiliation-only frame, the usual design, would never have seen this work. It is one of the works that make the case for inverting the frame.

Bibliographic record

VenueInternational Journal of Chemistry · 2017
Typearticle
Languageen
FieldChemistry
TopicAnalytical Methods in Pharmaceuticals
Canadian institutionsnot available
Fundersnot available
KeywordsChemistryLidocaine HydrochlorideChloroformMolar absorptivityChromatographyRelative standard deviationExtraction (chemistry)LidocaineDetection limitHydrochlorideStoichiometrySpectrophotometryAccuracy and precisionAnalytical Chemistry (journal)Organic chemistry

Abstract

fetched live from OpenAlex

Simple, selective and highly detectable spectrophotometric method has been developed and validated for the determination of Lidocaine hydrochloride in standard and commercial solutions .The method is based on the formation of a soluble colored Lidocaine hydrochloride-eriochrome black T ion-pair complex at pH 1.80. The colored complex was extracted quantitatively into chloroform and measured at 508 nm. Beer’s law was obeyed in the concentration range of 0.10-10 mg L -1 with molar absorptivity of 2.3623 x104 L mol-1 cm-1.The limits of detection and quantification were 0.024 mg L -1, and 0.100 mg L -1 respectively. Using Job’s continuous variations method, the stoichiometry of the ion-pair complex was found to be 1:1. Intra-day accuracy and precision of the method were estimated with a relative error (0.57%), and the relative standard deviation (0.25-1.23). This developed method has been successfully employed to determine concentration of Lidocaine hydrochloride in injection and spray without interference by the common co-formulated substances.The numerical results obtained using both proposed and official methods were in concordance with each other.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.005
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.044
Threshold uncertainty score0.998

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.005
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.050
GPT teacher head0.449
Teacher spread0.399 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it