OPACIFICATION OF SCLERAL-SUTURED AKREOS AO60 INTRAOCULAR LENS AFTER VITRECTOMY WITH GAS TAMPONADE: CASE SERIES
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
BACKGROUND/PURPOSE: We report the first two cases of postoperative opacification of scleral-sutured Akreos AO60 intraocular lens after vitrectomy with the gas tamponade. METHODS: Two patients with ectopia lentis underwent pars plana vitrectomy, pars plana lensectomy, and scleral fixation of an Akreos AO60 intraocular lens with Gore-Tex suture. Retinal breaks were noted during vitrectomy and consequently intravitreal gas tamponade was used after endolaser retinopexy. Postoperatively, both patients developed intraocular lens opacification but maintained excellent visual acuity; however, one patient developed bothersome though tolerable photophobia. CONCLUSION: Although still an excellent option for the management of surgical aphakia in the absence of capsular support, caution should be taken when using a hydrophilic secondary intraocular lens, such as Akreos AO60, during vitreoretinal surgery if gas is required.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.001 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.001 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it