MétaCan
Menu
Back to cohort
Record W2760003692 · doi:10.1116/1.5005925

Using a high-stability quartz-crystal microbalance to measure and model the chemical kinetics for gases in and on metals: Oxygen in gold

2018· article· en· W2760003692 on OpenAlexafffund
A. J. Slavin

Bibliographic record

VenueJournal of Vacuum Science & Technology A Vacuum Surfaces and Films · 2018
Typearticle
Languageen
FieldEngineering
TopicAcoustic Wave Resonator Technologies
Canadian institutionsTrent University
FundersNatural Sciences and Engineering Research Council of CanadaTrent University
KeywordsQuartz crystal microbalanceTorrOxygenAnalytical Chemistry (journal)ChemistryDiffusionAuger electron spectroscopyLimiting oxygen concentrationCrystal (programming language)Chemical physicsPhysical chemistryThermodynamicsAdsorption

Abstract

fetched live from OpenAlex

This paper describes the use of a high-stability quartz-crystal microbalance (QCM) to measure the mass of a gas absorbed on and in the metal electrode on the quartz oscillator, when the gas pressure is low and the gas can be considered as rigidly attached to the metal, so the viscosity effects are negligible. This provides an absolute measure of the total mass of gas uptake as a function of time, which can be used to model the kinetic processes involved. The technique can measure diffusion parameters of gases in metals close to room temperature at gas pressures much below one atmosphere, as relevant to surface processes such as atomic layer deposition and model studies of heterogeneous catalysis, whereas traditional diffusion measurements require temperatures over 400 °C at gas pressures of at least a few Torr. A strong aspect of the method is the ability to combine the “bulk” measurement of absorbed mass by a QCM with a surface-sensitive technique such as Auger electron spectroscopy in the same vacuum chamber. The method is illustrated using atomic oxygen, formed under O2 gas at 6 × 10−5 Torr in the presence of a hot tungsten filament, interacting with the gold electrode on a QCM crystal held at 52 to 120 °C. Some of the incident oxygen forms a surface oxide which eventually blocks more uptake, and the rest (about 80%) indiffuses. Surprisingly, the rate of oxygen uptake initially increases with the amount of oxygen previously absorbed; therefore, the measured oxygen uptake with time is reproducible only if preadsorption of oxygen conditions the sample. Temperatures above 130 °C are necessary for measurable thermal desorption, but all the oxygen can be removed by CO scavenging at all temperatures of these experiments. Simple kinetic models are developed for fitting the experimental QCM data to extract parameters including those controlling adsorption of oxygen, the CO scavenging probability, and limits on the diffusion jump frequency of dissolved oxygen. The reproducibility of the data and the good model fits to it provide proof-of-principle for the technique.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.650
Threshold uncertainty score0.564

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.029
GPT teacher head0.264
Teacher spread0.236 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2018
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Vacuum Science & Technology A Vacuum Surfaces and FilmsSame topicAcoustic Wave Resonator TechnologiesFrench-language works237,207