MétaCan
Menu
Back to cohort
Record W2761151032 · doi:10.1177/1179559x17734227

Efficacy of Continuous Positive Airway Pressure Treatment in Patients with Cardiac Arrhythmia and Obstructive Sleep Apnea: What is the Evidence?

2017· article· en· W2761151032 on OpenAlexaff
Asmaa M. Abumuamar, Tatyana Mollayeva, Paul Sandor, David Newman, Kumaraswamy Nanthakumar, Colin M. Shapiro

Bibliographic record

VenueClinical Medicine Insights Therapeutics · 2017
Typearticle
Languageen
FieldMedicine
TopicObstructive Sleep Apnea Research
Canadian institutionsHealth Sciences CentreToronto Rehabilitation InstituteSunnybrook Health Science CentreToronto Western HospitalUniversity of TorontoUniversity Health Network
Fundersnot available
KeywordsMedicineContinuous positive airway pressureObstructive sleep apneaCardiologyCardiac arrhythmiaInternal medicineObservational studyHeart failurePositive airway pressureEjection fractionConfoundingCoronary artery diseaseSleep apneaIntensive care medicineAtrial fibrillation

Abstract

fetched live from OpenAlex

Numerous studies have been conducted in the past few decades on obstructive sleep apnea (OSA) as an independent risk factor for the development and progression of cardiac arrhythmia. Treatment with continuous positive airway pressure (CPAP) therapy lowers blood pressure, improves ejection fraction in patients with heart failure, and decreases the need of revascularization procedures in patients with coronary artery disease. However, there has been little published discussion regarding the effect of CPAP treatment on cardiac arrhythmia in patients with OSA. We aimed to summarize scientific evidence regarding the utility of CPAP treatment in managing the recurrence and severity of different types of cardiac arrhythmia. We retrieved articles published in English before December 2016, through database search of PubMed, CENTRAL, and Embase. All peer-reviewed experimental, comparative, and other observational studies focused on adults were considered eligible. Several studies documented positive changes in arrhythmia frequency and severity with CPAP application, irrespective of type of arrhythmia, study methodology, or setting. However, the available evidence on the impact of CPAP treatment on the frequency and severity of cardiac arrhythmia is limited by heterogeneity of data. The duration of CPAP application, compliance with treatment, and baseline severity of OSA and cardiac pathology are important confounding factors that influence the effect of CPAP treatment. We emphasize the need for agreement on a core set of relevant predictors of the magnitude of the effect. Future research should carefully address these factors and their influence on the potential therapeutic ability of CPAP treatment to improve cardiac outcomes and reduce the risks of adverse cardiac and noncardiac effects associated with untreated OSA.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesScience and technology studies
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.432
Threshold uncertainty score0.999

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.003
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.052
GPT teacher head0.369
Teacher spread0.317 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueClinical Medicine Insights TherapeuticsSame topicObstructive Sleep Apnea ResearchFrench-language works237,207