MétaCan
Menu
Back to cohort
Record W2761596584 · doi:10.5301/jva.5000785

Predicting tissue plasminogen activator use and success in in-center hemodialysis patients

2017· article· en· W2761596584 on OpenAlexaff
Sarah Daisy Kosa, Chenglin Ye, Lehana Thabane, Amiram Gafni, Charmaine E. Lok

Bibliographic record

VenueThe Journal of Vascular Access · 2017
Typearticle
Languageen
FieldHealth Professions
TopicCentral Venous Catheters and Hemodialysis
Canadian institutionsMcMaster UniversityToronto General HospitalImpactUniversity Health Network
Fundersnot available
KeywordsMedicineHemodialysisBody mass indexCatheterHemodialysis CatheterTissue plasminogen activatorDialysisHazard ratioSurgeryLogistic regressionInternal medicineConfidence interval

Abstract

fetched live from OpenAlex

INTRODUCTION: Hemodialysis catheter malfunction is problematic. We aimed to determine clinical, catheter, and hemodialysis variables that predict: (i) catheter malfunction requiring recombinant tissue-plasminogen activator (TPA) treatment and (ii) the success of TPA administration. METHODS: Clinical, catheter, and hemodialysis variables were collected from a cohort of 559 catheters (141,526 catheter days) in 175 hemodialysis patients (2008-2011). Time to, and predictors of, catheter malfunction were determined for all catheters and primary catheters only, analyzed by Cox-proportional hazard model, multi-variable logistic regression model, and mixed-effect logistic regression models. Success of TPA use was determined immediately, next day, and two weeks after use. RESULTS: Shorter time to first TPA administration in all patient's catheters was associated with increased body mass index (hazard ratio [HR] = 1.06, 1.01-1.11, p = 0.03) and being of black race (HR = 3.05, 1.65-5.67, p<0.01). Primary TPA administration success at two weeks among primary catheters was associated with increased mean peak venous pressure before TPA administration (odds ratio [OR] = 1.03, 1.01-1.06, p<0.01) and decreased mean of the lowest systolic blood pressure measure for the three dialysis sessions prior to TPA administration (OR = 0.95, 0.91-0.99, p = 0.02). TPA administration success at two weeks among all catheters was associated with decreasing body mass index (OR = 0.84, CI 0.73-0.96, p = 0.01) and having diabetes (OR = 7.19, 1.40-36.81, p = 0.02). CONCLUSIONS: Both patient and dialysis predictors of TPA use and success were identified in this study, which may be useful for fine-tuning catheter management protocols to target hemodialysis patients at high risk of catheter malfunction.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.004
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.053
GPT teacher head0.366
Teacher spread0.313 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueThe Journal of Vascular AccessSame topicCentral Venous Catheters and HemodialysisFrench-language works237,207