MétaCan
Menu
Back to cohort
Record W2763164546 · doi:10.1002/dta.2322

Implementation of AICAR analysis by GC‐C‐IRMS for anti‐doping purposes

2017· article· en· W2763164546 on OpenAlexfundno aff
Corinne Buisson, C. Frelat, Cynthia Mongongu, Nicolas Martinat, Michel Audran

Bibliographic record

VenueDrug Testing and Analysis · 2017
Typearticle
Languageen
FieldMedicine
TopicHormonal and reproductive studies
Canadian institutionsnot available
FundersWorld Anti-Doping Agency
KeywordsDerivatizationChemistryChromatographyHigh-performance liquid chromatographySilylationGas chromatographyGas chromatography–mass spectrometryMass spectrometryOrganic chemistry

Abstract

fetched live from OpenAlex

AICAR (5-aminoimidazole-4-carboxamide-1-β-D-ribofuranoside), is a naturally occurring substance which is part to the World Anti-Doping Agency (WADA) Prohibited List. It is claimed to improve physical performance when administered as a supplement. As for other endogenous compounds such as steroids, the gas chromatography-combustion-isotope ratio mass spectrometry (GC-C-IRMS) analysis remains an efficient tool to differentiate endogenous substances from exogenous ones. A protocol was described in the literature for the analysis of AICAR by GC-C-IRMS. The aim of the present study was to implement this protocol in our laboratory and to propose solutions to avoid the difficulties encountered. The first point discussed in this study is the derivatization step. Due to the structure of the AICAR molecule, conventional derivatization for GC-C-IRMS such as acetylation could not be applied and silylation was preferred. The improvement of the derivatives stability was achieved thanks to several derivatization conditions tested. This adjustment led to a reproducible derivatization pattern with the 3-TMS form as major derivative product. The second point discussed in this study is the diminution of extracts' background noise. Indeed, the implementation of the published protocol was not easy due to high performance liquid chromatography (HPLC) problems encountered when concentrated urine was injected into our system. Also, too many interferences in the endogenous reference compound fractions were observed. The addition of both a wash step before the HPLC purification and a HPLC purification step for the endogenous reference compound (ERC) fraction allowed us to increase the robustness of the method. This study presents the modified protocol compared to the original protocol as well as the evaluation of the whole method performances. Copyright © 2017 John Wiley & Sons, Ltd.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.004
Threshold uncertainty score0.015

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.004
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0030.002
Science and technology studies0.0010.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0020.002
Insufficient payload (model declined to judge)0.0040.003

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.038
GPT teacher head0.355
Teacher spread0.317 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueDrug Testing and AnalysisSame topicHormonal and reproductive studiesFrench-language works237,207