MétaCan
Menu
← Back to cohort

Abstract 15798: Real Time MRI Based Atrial Cryoablation

2014· article· en· W2766422375 on OpenAlexaffabout
Ravi Ranjan, Eugene Kholmovski, Nicolas Coulombe, Joshua Silvernagel, Nassir Marrouche

Bibliographic record

VenueCirculation · 2014
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsMedtronic (Canada)
Fundersnot available
KeywordsMedicineCryoablationAblationBalloonOcclusionRadiologyPulmonary veinBalloon catheterOstiumNuclear medicineCatheterSurgeryCardiology

Abstract

fetched live from OpenAlex

Introduction: Balloon cryoablation is being increasingly used for pulmonary vein isolation. Acute determination of lesion permanency cannot be ascertained directly, but is inferred by PV occlusion and acute PV isolation. We aimed to determine if direct confirmation of vessel occlusion and lesion formation could be visualized in real time in a MRI system using a novel MRI compatible cryo balloon catheter. Methods: We used a canine model (n=3) and a MRI compatible cryo balloon catheter built for animal use (Medtronic CryoCath, Montreal, Canada). The procedure was performed in a 3T (Verio, Siemens) MR scanner. The MRI compatible 28 mm cryo balloon was advanced into the right atrium (RA) via the femoral vein under MRI guidance. Gadolinium based contrast (Multihance) was injected to confirm vessel occlusion. The superior vena cava (SVC) - RA junction was frozen for 3 mins. Post ablation, late gadolinium enhancement MRI (LGE-MRI) was obtained acutely to confirm the ablation. The heart was excised to confirm the tissue changes. Results: Panel A shows the inflated balloon at the SVC ostium. Panel B shows contrast injected in the SVC confirming its occlusion. Panel C is an MR image taken during the freeze cycle. Panel D is an LGE-MRI showing enhancement along the SVC wall confirming ablation. Panel E is an axial view of the SVC confirming circumferential ablation with no apparent gaps. The ablation completeness was confirmed in pathology. Conclusion: A real time MR-based balloon cryo ablation system was implemented. It allows real time confirmation of vessel occlusion, visualization of a freeze zone and visual confirmation of tissue changes from ablation in the pre-clinical setting.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Other · Consensus signal: none
Teacher disagreement score0.004
Threshold uncertainty score0.012

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0040.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.017
GPT teacher head0.302
Teacher spread0.285 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreOther

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2014
Admission routes2
Has abstractyes

Explore more

Same venueCirculation→Same topicAdvanced MRI Techniques and Applications→French-language works237,207→