MétaCan
Menu
Back to cohort
Record W2766784511 · doi:10.1177/1744259117735465

Buildings with environmental quality management, part 2: Integration of hydronic heating/cooling with thermal mass

2017· article· en· W2766784511 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueJournal of Building Physics · 2017
Typearticle
Languageen
FieldEngineering
TopicBuilding Energy and Comfort Optimization
Canadian institutionsMcMaster University
Fundersnot available
KeywordsEnclosureArchitectural engineeringHeat exchangerThermal massMasonryIntegrated designProcess (computing)System integrationZero-energy buildingThermal comfortMechanical engineeringThermal energy storageEngineeringCivil engineeringThermalEnergy consumptionComputer scienceMeteorologyElectrical engineering

Abstract

fetched live from OpenAlex

The quest for a sustainable built environment brought dramatic changes to architectural design because of the integrated design process. The integrated design process is the modern way to realize “performance architecture,” that is, design with a view to field performance. Integrated design process permits merging of concepts from passive-house designs, solar engineering, and an integration of the building enclosure with mechanical services. In part 1 of this series, the emergence of many new multi-functional materials was discussed. Yet, current innovation is guided by lessons from history. Thermal mass in heavy masonry buildings allowed periodic heating. The authors postulate integration of a hydronic heating system with the walls and the use of smart temperature control of the heating system to modify and optimize the thermal mass contribution. To use the mass of a building, one must accept transient temperature conditions where the indoor temperature varies but is confined by comfort requirements for both summer and winter conditions. On the other side, resiliency requirements dictate that in the absence of electricity the air temperature does not fall below about 12°C over a period of several hours. This requirement implies that summer cooling will likely be separated from the heating systems and that operation of a low-energy building is heavily dependent on the design of smart control systems. Analysis of control systems provided in this article for earth-to-air heat exchangers and cooling of houses with lightweight walls lead us to the requirements of separation between heating and ventilation and needs for different sources of fresh air. Finally, a new concept emerges.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.551
Threshold uncertainty score0.519

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.013
GPT teacher head0.229
Teacher spread0.217 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it