A Compartmentalization & Ventilation System Retrofit Strategy for High-Rise Residential Buildings in Cold Climates
Bibliographic record
Abstract
This research proposes a rehabilitation strategy for aging high-rise residential buildings involving suite compartmentalization and a modified ventilation strategy. The impact of this retrofit strategy on energy consumption and fuel mix is investigated through computer simulation using a calibrated EnergyPlus model of a case study building. Findings show a 51% (48.5 ekWh/m 2 ) reduction in overall annual heating energy for the building, with electrical space heating energy decreasing by 20% (10.5 kWh/m 2 ), and natural gas consumption for mechanical ventilation decreasing by 87% (38.0 ekWh/m 2 ). The building’s overall annual carbon footprint decreased by 29%, or approximately 20.2 tCO 2 e (3.9 kgCO 2 e/m 2 ).
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".