MétaCan
Menu
Back to cohort
Record W2767511753 · doi:10.1115/1.4038358

Operator Bias Errors Are Reduced Using Standing Marker Alignment Device for Repeated Visit Studies

2017· article· en· W2767511753 on OpenAlexafffund
Laura Hutchinson, Joel Schwartz, Amy M. Morton, Irene S. Davis, Kevin J. Deluzio, Michael J. Rainbow

Bibliographic record

VenueJournal of Biomechanical Engineering · 2017
Typearticle
Languageen
FieldHealth Professions
TopicBalance, Gait, and Falls Prevention
Canadian institutionsQueen's University
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsPalpationKinematicsRepeatabilityGaitArtifact (error)Gait analysisComputer scienceArtificial intelligenceComputer visionOrientation (vector space)CalibrationAnklePhysical medicine and rehabilitationMotion captureMedicineMotion (physics)MathematicsAnatomySurgeryPhysicsGeometry

Abstract

fetched live from OpenAlex

When optical motion capture is used for motion analysis, reflective markers or a digitizer are typically used to record the location of anatomical landmarks identified through palpation. The landmarks are then used to construct anatomical coordinate systems. Failure to consistently identify landmarks through palpation over repeat tests creates artifacts in the kinematic waveforms. The purpose of this work was to improve intra- and inter-rater reliability in determining lower limb anatomical landmarks and the associated anatomical coordinate systems using a marker alignment device (MAD). The device aids the subject in recreating the same standing posture over multiple tests, and recreates the anatomical landmarks from previous static calibration trials. We tested three different raters who identified landmarks on eleven subjects. The subjects performed walking trials and their gait kinematics were analyzed with and without the device. Ankle kinematics were not improved by the device suggesting manual palpation over repeat visits is just as effective as the MAD. Intra-class correlation coefficients between gait kinematics registered to the reference static trial and registered to follow-up static trials with and without the device were improved between 1% and 33% when the device was used. Importantly, out-of-plane hip and knee kinematics showed the greatest improvements in repeatability. These results suggest that the device is well suited to reducing palpation artifact during repeat visits to the gait lab.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.925
Threshold uncertainty score0.608

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0010.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.148
GPT teacher head0.427
Teacher spread0.279 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2017
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Biomechanical EngineeringSame topicBalance, Gait, and Falls PreventionFrench-language works237,207