Non-invasive spinal vibration testing using ultrafast ultrasound imaging: A new way to measure spine function
Bibliographic record
Abstract
The extremely high frame-rate of ultrafast ultrasound imaging has enabled the possibility to image extremely fast events on the order of thousands of frames/sec. With the success of ultrafast imaging across a wide variety of disciplines, we now explore the ability of ultrafast imaging to capture spinal vibrations for non-invasive spinal testing in living subjects. Previously, we have shown that accelerometer-based vibration testing in cadaveric models can reveal the presence, location and magnitude of spinal pathology. However, this process remains an invasive procedure as current non-invasive sensors are inadequate. In this experiment, we investigate the ability of non-invasive ultrafast ultrasound to quantify in-vivo vertebral vibration response across a broad range of frequencies (10-100 Hz) in an anesthetized pig model.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.001 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.001 | 0.000 |
| Science and technology studies | 0.000 | 0.001 |
| Scholarly communication | 0.001 | 0.001 |
| Open science | 0.001 | 0.000 |
| Research integrity | 0.001 | 0.001 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".