MétaCan
Menu
Back to cohort
Record W2770245150 · doi:10.2174/1874325001711011337

Effect of Femoral Stem Modular Neck’s Material on Metal Ion Release

2017· article· en· W2770245150 on OpenAlexaff
Janie Barry, Marc-Olivier Kiss, Vincent Massé, Martin Lavigne, Jihad Matta, Pascal‐André Vendittoli

Bibliographic record

VenueThe Open Orthopaedics Journal · 2017
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsUniversité de MontréalHôpital Maisonneuve-Rosemont
Fundersnot available
KeywordsMedicineImplantSurgeryFemoral neckModular designInternal medicine

Abstract

fetched live from OpenAlex

Background: In recent decades, the popularity of modular necks in total hip arthroplasty (THA) has increased since modular necks offer the potential to restore the patient’s native anatomy, and thus improve stability. Unfortunately, modular necks are associated with higher complication rates, including implant fracture and modular junction corrosion with adverse local tissue reaction to metal debris. Objective: The objective of this study was to determine the impact of modular neck material on titanium (Ti), chrome (Cr), and cobalt (Co) metal ion levels in patients who underwent a THA with Ti femoral stem, Ti or CrCo modular neck, and ceramic-on-ceramic (CoC) bearing. Methods: Whole blood Ti, Cr, and Co levels were compared at a minimum 1-year follow-up in 36 patients who underwent unilateral, primary CoC large-diameter head THA with Profemur ® Preserve modular femoral stems (MicroPort, Arlington, TX, USA). Results: Higher Co concentrations were observed in the CrCo modular neck group (0.46 versus 0.26 µg/l in the Ti neck group, P=0.004) and higher Ti concentrations were observed in the Ti modular neck group (1.98 vs 1.59 µg/l in the CrCo neck group, P=0.007). However, these differences were not clinically meaningful since the absolute values remained within what is considered the safe range of Ti, Cr, and Co ions in whole blood. No patients were re-operated or revised. Conclusion: Modular neck materials had an impact on whole blood metal ion levels but the concentrations measured remained within the safe range at 1-year follow-up. There were no indirect signs of modular junction corrosion with either CrCo or Ti femoral necks.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.826
Threshold uncertainty score0.892

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0030.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0010.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.026
GPT teacher head0.315
Teacher spread0.288 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations10
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueThe Open Orthopaedics JournalSame topicOrthopaedic implants and arthroplastyFrench-language works237,207