MétaCan
Menu
Back to cohort
Record W2770342819 · doi:10.1148/radiol.2017162620

Fractional Flow Reserve Estimated at Coronary CT Angiography in Intermediate Lesions: Comparison of Diagnostic Accuracy of Different Methods to Determine Coronary Flow Distribution

2017· article· en· W2770342819 on OpenAlexaff
Satoru Kishi, Andreas A. Giannopoulos, Anji Tang, Nahoko Kato, Yiannis S. Chatzizisis, Carole Dennie, Yu Horiuchi, Kengo Tanabe, João A.C. Lima, Frank J. Rybicki, Dimitris Mitsouras

Bibliographic record

VenueRadiology · 2017
Typearticle
Languageen
FieldMedicine
TopicCoronary Interventions and Diagnostics
Canadian institutionsOttawa Hospital
FundersNational Institute of Biomedical Imaging and BioengineeringToshiba Medical Systems
KeywordsMedicineFractional flow reserveCoronary angiographyRadiologyDiagnostic accuracyCoronary flow reserveDistribution (mathematics)CardiologyAngiographyNuclear medicineInternal medicineBlood flowMyocardial infarctionMathematical analysis

Abstract

fetched live from OpenAlex

Purpose To compare the diagnostic accuracy of different computed tomographic (CT) fractional flow reserve (FFR) algorithms for vessels with intermediate stenosis. Materials and Methods This cross-sectional HIPAA-compliant and human research committee–approved study applied a four-step CT FFR algorithm in 61 patients (mean age, 69 years ± 10; age range, 29–89 years) with a lesion of intermediate-diameter stenosis (25%–69%) at CT angiography who underwent FFR measurement within 90 days. The per-lesion diagnostic performance of CT FFR was tested for three different approaches to estimate blood flow distribution for CT FFR calculation. The first two, the Murray law and the Huo-Kassab rule, used coronary anatomy; the third used contrast material opacification gradients. CT FFR algorithms and CT angiography percentage diameter stenosis (DS) measurements were compared by using the area under the receiver operating characteristic curve (AUC) to detect FFRs of 0.8 or lower. Results Twenty-five lesions (41%) had FFRs of 0.8 or lower. The AUC of CT FFR determination by using contrast material gradients (AUC = 0.953) was significantly higher than that of the Huo-Kassab (AUC = 0.882, P = .043) and Murray law models (AUC = 0.871, P = .033). All three AUCs were higher than that for 50% or greater DS at CT angiography (AUC = 0.596, P < .001). Correlation of CT FFR with FFR was highest for gradients (Spearman ρ = 0.80), followed by the Huo-Kassab rule (ρ = 0.68) and Murray law (ρ = 0.67) models. All CT FFR algorithms had small biases, ranging from −0.015 (Murray) to −0.049 (Huo-Kassab). Limits of agreement were narrowest for gradients (−0.182, 0.147), followed by the Huo-Kassab rule (−0.246, 0.149) and the Murray law (−0.285, 0.256) models. Conclusion Clinicians can perform CT FFR by using a four-step approach on site to accurately detect hemodynamically significant intermediate-stenosis lesions. Estimating blood flow distribution by using coronary contrast opacification variations may improve CT FFR accuracy. © RSNA, 2017 Online supplemental material is available for this article.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.009
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.072
Threshold uncertainty score0.999

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.009
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.075
GPT teacher head0.418
Teacher spread0.343 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations41
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueRadiologySame topicCoronary Interventions and DiagnosticsFrench-language works237,207