MétaCan
Menu
Back to cohort
Record W2770974777 · doi:10.1371/journal.pone.0187885

Evaluating the efficacy of an active compression brace on orthostatic cardiovascular responses

2017· article· en· W2770974777 on OpenAlexafffund
Hadi Moein, Ramandeep Jhalli, Andrew P. Blaber, Victoria E. Claydon, Carlo Menon

Bibliographic record

VenuePLoS ONE · 2017
Typearticle
Languageen
FieldMedicine
TopicCardiovascular Syncope and Autonomic Disorders
Canadian institutionsSimon Fraser University
FundersCanadian Institutes of Health ResearchNatural Sciences and Engineering Research Council of CanadaCanada Research Chairs
KeywordsMedicineOrthostatic vital signsHeart rateSupine positionBlood pressurePlaceboPresyncopeOrthostatic intoleranceAmbulatoryCircumferenceTreadmillCardiologyHemodynamicsAnesthesiaInternal medicineMathematics

Abstract

fetched live from OpenAlex

Orthostatic intolerance, one of the principle causes of syncope, can occur secondary to concomitant venous pooling and enhanced capillary filtration. We aimed to evaluate a prototype portable calf active compression brace (ACB) designed to improve orthostatic haemodynamic control. Fourteen healthy volunteers participated in a randomized, placebo controlled, cross-over, double-blind study. Testing consisted of head-upright tilting and walking on a treadmill conducted on two consecutive days with a pair of ACBs wrapped around both calves. The ACB was actuated on one test day, but not on the other (placebo). Wearability, comfort, and ambulatory use of the ACB were assessed using questionnaires. The average calf pressure exerted by the ACB was 46.3±2.2 mmHg and the actuation pressure was 20.7±1.7 mmHg. When considering the differences between ACB actuation and placebo during tilt after supine rest there were trends for a larger stroke volume (+5.20±2.34%, p = 0.05) and lower heart rate (-5.12±2.41%, p = 0.06) with ACB actuation, with no effect on systolic arterial pressure (+4.86±3.41%, p = 0.18). The decrease in stroke volume after ten minutes of tilting was positively correlated with the height:calf circumference (r = 0.464; p = 0.029; n = 22; both conditions combined). The increase in heart rate after ten minutes of tilting was negatively correlated with the height:calf circumference (r = -0.485; p = 0.022; n = 22; both conditions combined) and was positively correlated with the average calf circumference (r = 0.539; p = 0.009; n = 22; both conditions combined). Participants reported good ACB wearability and comfort during ambulatory use. These data verify that the ACB increased stroke volume during tilting in healthy controls. Active calf compression garments may be a viable option for the management of orthostatic intolerance.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.783
Threshold uncertainty score0.346

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.137
GPT teacher head0.362
Teacher spread0.225 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations10
Published2017
Admission routes2
Has abstractyes

Explore more

Same venuePLoS ONESame topicCardiovascular Syncope and Autonomic DisordersFrench-language works237,207