MétaCan
Menu
Back to cohort
Record W2771915576 · doi:10.6113/jpe.2017.17.6.1658

An Enhanced Instantaneous Circulating Current Control for Reactive power and Harmonic Load Sharing in Islanded Microgrids

2017· article· en· W2771915576 on OpenAlexaff
Iman Lorzadeh, Hossein Askarian Abyaneh, Mehdi Savaghebi, Omid Lorzadeh, Alireza Bakhshai, Josep M. Guerrero

Bibliographic record

VenueVBN Forskningsportal (Aalborg Universitet) · 2017
Typearticle
Languageen
FieldEngineering
TopicMicrogrid Control and Optimization
Canadian institutionsQueen's University
Fundersnot available
KeywordsCurrent (fluid)HarmonicAC powerControl theory (sociology)Load sharingPower (physics)Control (management)Computer scienceElectrical engineeringEngineeringPhysicsDistributed computingAcousticsThermodynamics

Abstract

fetched live from OpenAlex

To address inaccurate load demand sharing problems among parallel inverter-interfaced voltage-controlled distributed generation (DG) units in islanded microgrids with different DG power ratings and mismatched feeder impedances, an enhanced voltage control scheme based on actively compensation of circulating voltage drops is proposed in this paper. Using proposed strategy, reactive power and harmonic currents sharing are shared accurately and proportionally without knowledge of feeder impedances. As the proposed local controller consists of two well-separated fundamental and harmonic voltage control branches, the reactive power and harmonic currents can be independently shared without having remarkable effects on the amplitude and quality of the DGs voltage, even if nonlinear (harmonic) loads are directly connected at the output terminal of units. In addition, the accurate load sharing can also be attained when the plug-and-play performance of DGs and various loading conditions are applied to the system. The effects of communication failures and latency on the performance of proposed strategy are also explored. Design process of the proposed control system is presented in detail and comprehensive simulation studies on a three-phase microgrid are provided to validate the effectiveness of the proposed control method.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.001
Threshold uncertainty score0.002

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.006
GPT teacher head0.216
Teacher spread0.210 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueVBN Forskningsportal (Aalborg Universitet)Same topicMicrogrid Control and OptimizationFrench-language works237,207