MétaCan
Menu
Back to cohort
Record W2777803527 · doi:10.5662/wjm.v7.i4.139

Quantitative comparison of cranial approaches in the anatomy laboratory: A neuronavigation based research method

2017· article· en· W2777803527 on OpenAlexaff
Francesco Doglietto, Jimmy Qiu, Mayoorendra Ravichandiran, Ivan Radovanovic, Francesco Belotti, Anne Agur, Gelareh Zadeh, Marco Maria Fontanella, Walter Kucharczyk, Fred Gentili

Bibliographic record

VenueWorld Journal of Methodology · 2017
Typearticle
Languageen
FieldMedicine
TopicSurgical Simulation and Training
Canadian institutionsUniversity of TorontoUniversity Health NetworkToronto Western HospitalSurgical Specialties (Canada)
Fundersnot available
KeywordsNeuronavigationComputer scienceVisualizationSoftwareImaging phantomMedical physicsArtificial intelligenceComputer visionRadiologyMedicineMagnetic resonance imaging

Abstract

fetched live from OpenAlex

AIM: To describe the development and validation of a novel neuronavigation-based method, which allows the quantification of the anatomical features that define an approach, as well as real-time visualization of the surgical pyramid. METHODS: The method was initially developed with commercially-available hardware for coordinate collection (a digitizer and a frameless navigation system) and software for volume rendering; dedicated neuronavigation software (ApproachViewer, part of GTx-UHN) was then developed. The accuracy of measurements and the possibility of volumetric rendering of surgical approaches simulated in a phantom were compared among three different methods and commercially-available radiological software. In the anatomy laboratory, ApproachViewer was applied to the comparative quantitative analysis of multiple neurosurgical approaches and was used by many surgeons who were untrained for the research method. RESULTS: The accuracy of ApproachViewer is comparable to commercially-available radiological software. In the anatomy laboratory, the method appears versatile. The system can be easily used after brief training. ApproachViewer allows for real-time evaluation and comparison of surgical approaches, as well as post-dissection analyses of collected data. The accuracy of the method depends on the navigation registration: with a 1-2 mm registration error, it is adequate for evaluation and comparison of most neurosurgical approaches. CONCLUSION: This new research method and software allows semi-automated visualization, quantification, and comparison of neurosurgical approaches in the anatomy laboratory.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.021
metaresearch head score (Gemma)0.008
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.288
Threshold uncertainty score0.901

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0210.008
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.758
GPT teacher head0.600
Teacher spread0.158 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations20
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueWorld Journal of MethodologySame topicSurgical Simulation and TrainingFrench-language works237,207