MétaCan
Menu
Back to cohort
Record W2780479930 · doi:10.1097/ccm.0000000000002955

Chloride and Other Electrolyte Concentrations in Commonly Available 5% Albumin Products

2017· article· en· W2780479930 on OpenAlexaffabout
Alison Lai, Michelle P. Zeller, Tina Millen, Peter A. Kavsak, Wojciech Szczeklik, Allahna Elahie, Waleed Alhazzani, Frédérick D’Aragon, Roman Jaeschke, François Lamontagne, Timothy Karachi, Maureen O. Meade, Bram Rochwerg

Bibliographic record

VenueCritical Care Medicine · 2017
Typearticle
Languageen
FieldMedicine
TopicTrauma, Hemostasis, Coagulopathy, Resuscitation
Canadian institutionsUniversité de SherbrookeImpactMcMaster University
Fundersnot available
KeywordsMedicineAlbuminResuscitationElectrolyteSepsisChlorideIntensive careInternal medicineSurgeryIntensive care medicineChemistry

Abstract

fetched live from OpenAlex

OBJECTIVE: Use of hyperchloremic IV fluids for resuscitation in sepsis may be associated with increased mortality and use of renal replacement therapy. After crystalloids, 5% human albumin represents the second most common resuscitation fluid in the ICU. Its chloride concentration is rarely considered in the clinical setting. This study quantifies previously undocumented chloride concentrations of three 5% albumin solutions using biochemical analysis. DESIGN: We performed blinded analysis of the electrolyte concentration of albumin samples obtained directly from the national blood supplier (Canadian Blood Services). Two-tailed independent t tests were performed for all possible comparative analyses. Analysis of variance testing was performed for relevant three-way comparisons. Significance threshold was set at p less than 0.05. SETTING: All samples were analyzed in the core laboratory at an academic hospital associated with McMaster University in Hamilton, Ontario, Canada. SUBJECTS: We analyzed 65 albumin samples from three available brands obtained through Canadian Blood Services. They include Plasbumin (n = 21), Alburex (n = 24), Octalbin (n = 20). INTERVENTION: Laboratory technologists blinded to product identification measured the concentration of electrolytes, extended electrolytes, lactate, and albumin of each sample using the Abbott ARCHITECT c8000 chemistry analyzer. MEASUREMENTS AND MAIN RESULTS: The mean chloride concentration of Plasbumin, Alburex, and Octalbin, respectively, were 109.4 mmol/L (SD, 1.3), 123.6 mmol/L (SD, 1.3), and 136.8 mmol/L (SD, 0.4). The mean sodium concentration of Plasbumin, Alburex, and Octalbin, respectively, were 139.6 mmol/L (SD, 1.6), 137.3 mmol/L (SD, 2.2), and 149.4 mmol/L (SD, 0.5). The chloride and sodium concentration differed significantly for all two-way comparisons (p < 0.0001) and multiple comparison testing (p < 0.0001). CONCLUSION: This study is the first to identify and document a statistically significant variability in the chloride concentration of available 5% albumin products. This study has also informed a pilot randomized controlled trial examining the effect of administering high chloride versus low chloride fluids in critically ill patients with sepsis.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.006
Threshold uncertainty score0.011

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.004
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0020.001
Science and technology studies0.0000.001
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.051
GPT teacher head0.351
Teacher spread0.300 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations13
Published2017
Admission routes2
Has abstractyes

Explore more

Same venueCritical Care MedicineSame topicTrauma, Hemostasis, Coagulopathy, ResuscitationFrench-language works237,207