MétaCan
Menu
← Back to cohort
Record W2782664532 · doi:10.1115/imece2017-71514

Nonlinear Vibrations of Woven Dacron Aortic Prostheses Conveying Pulsatile Flow

2017· article· en· W2782664532 on OpenAlexafffund
Eleonora Tubaldi, Marco Amabili, Michael P. Paı̈doussis

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldMedicine
TopicAortic Disease and Treatment Approaches
Canadian institutionsMcGill University
FundersFonds de recherche du Québec – Nature et technologiesNatural Sciences and Engineering Research Council of CanadaCanada Research Chairs
KeywordsPulsatile flowOrthotropic materialMechanicsMaterials scienceNonlinear systemVibrationHarmonicsBiomedical engineeringAcousticsStructural engineeringPhysicsEngineeringFinite element method

Abstract

fetched live from OpenAlex

Woven Dacron grafts represent standard implants for replacements of the thoracic aorta in current medical practice. Wide knowledge about the distinctly different mechanical properties of the Dacron implants with respect to the native aorta is available in literature while very little is known about the dynamic behavior of these prostheses. This study addresses the dynamic response to pulsatile physiological blood flow and pressure of woven Dacron grafts currently used in thoracic aortic replacements. The structural model assumes a cylindrical orthotropic shell described by means of the nonlinear Novozhilov shell theory. Residual stresses because of pulsatile physiological pressurization are evaluated and included in the model. The pulsatile flowing fluid is formulated using a hybrid model that contains the unsteady effects obtained from linear potential flow theory and the viscous effects obtained from the unsteady time-averaged Navier–Stokes equations. Physiological waveforms of blood pressure and velocity are approximated with the first eight harmonics of the corresponding Fourier series. Coupled fluid-structure Lagrange equations for a non-material volume with wave propagation in case of pulsatile flow are utilized. Frequency-response curves in the physiological range show the geometrically nonlinear vibration response to pulsatile flow with several superharmonic resonance peaks in the high physiological frequency range. Different values of modal damping are considered; in the limit case of low modal damping values, flow-induced asymmetric vibration of the aortic prosthesis is possible. Finally, in order to reproduce the weave design of the woven Dacron fabrics, geometric imperfections are introduced in the structural model. The numerical natural frequencies of the pressurized prosthesis are compared with the experimental results obtained from the modal analysis of a woven Dacron graft.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.000
Threshold uncertainty score0.002

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.047
GPT teacher head0.319
Teacher spread0.272 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2017
Admission routes2
Has abstractyes

Explore more

Same topicAortic Disease and Treatment Approaches→French-language works237,207→