MétaCan
Menu
Back to cohort
Record W2783217734 · doi:10.1002/jmri.25929

Comparison of modified two‐point dixon and chemical shift encoded MRI water‐fat separation methods for fetal fat quantification

2018· article· en· W2783217734 on OpenAlexafffund
Stephanie A. Giza, Michael R. Miller, Prasiddha Parthasarathy, Barbra de Vrijer, Charles A. McKenzie

Bibliographic record

VenueJournal of Magnetic Resonance Imaging · 2018
Typearticle
Languageen
FieldMedicine
TopicPregnancy and preeclampsia studies
Canadian institutionsChildren’s Health Research InstituteWestern University
FundersCanadian Institutes of Health ResearchNatural Sciences and Engineering Research Council of CanadaCanada Research ChairsChildren's Health Research InstituteGeneral Electric
KeywordsIntraclass correlationMedicineNuclear medicineMagnetic resonance imagingPopulationFetusReproducibilityPregnancyRadiologyMathematicsBiologyStatistics

Abstract

fetched live from OpenAlex

BACKGROUND: Fetal fat is indicative of the energy balance within the fetus, which may be disrupted in pregnancy complications such as fetal growth restriction, macrosomia, and gestational diabetes. Water-fat separated MRI is a technique sensitive to tissue lipid content, measured as fat fraction (FF), and can be used to accurately measure fat volumes. Modified two-point Dixon and chemical shift encoded MRI (CSE-MRI) are water-fat separated MRI techniques that could be applied to imaging of fetal fat. Modified two-point Dixon has biases present that are corrected in CSE-MRI which may contribute to differences in the fat measurements. PURPOSE: To compare the measurement of fetal fat volume and FF by modified two-point Dixon and CSE-MRI. STUDY TYPE: Cross-sectional study for comparison of two MRI pulse sequences. POPULATION: Twenty-one pregnant women with singleton pregnancies. FIELD STRENGTH/SEQUENCE: 1.5T, modified two-point Dixon and CSE-MRI. ASSESSMENT: Manual segmentation of total fetal fat volume and mean FF from modified 2-point Dixon and CSE-MRI FF images. STATISTICAL TESTS: Reliability was assessed by calculating the intraclass correlation coefficient (ICC). Agreement was assessed using a one-sample t-test on the fat measurements difference values (modified two-point Dixon - CSE-MRI). The difference scores were tested against a value of 0, which would indicate that the measurements were identical. RESULTS: The fat volume and FF measured by modified two-point Dixon and CSE-MRI had excellent reliability, demonstrated by ICCs of 0.93 (P < 0.001) and 0.90 (P < 0.001), respectively. They were not in agreement, with CSE-MRI giving mean fat volumes 180 mL greater and mean FF 3.0% smaller than modified two-point Dixon. DATA CONCLUSION: The reliability between modified two-point Dixon and CSE-MRI indicates that either technique can be used to compare fetal fat measurements in different participants, but they are not in agreement possibly due to uncorrected biases in modified two-point Dixon. LEVEL OF EVIDENCE: 4 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.008
metaresearch head score (Gemma)0.020
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.008
Threshold uncertainty score0.040

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0080.020
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0020.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.050
GPT teacher head0.409
Teacher spread0.359 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2018
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Magnetic Resonance ImagingSame topicPregnancy and preeclampsia studiesFrench-language works237,207