Robust Chemiresistive Sensor for Continuous Monitoring of Free Chlorine Using Graphene-like Carbon

2018· article· en· 10 citations· W2784503954 on OpenAlex· 10.1021/acssensors.7b00884

Why is this work in the frame?

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

Canadian affiliationAn author listed a Canadian institution. This is the only route the usual frame has.
Canadian funderA Canadian agency funded it. The work may carry no Canadian affiliation at all.

Post-publication record

Nature
Retraction
Reason
Falsification/Fabrication of Data;Unreliable Results and/or Conclusions;
Date
5/18/2018 0:00
Flagged by OpenAlex?
Yes

Source: Retraction Watch, joined by DOI. OpenAlex records retraction as is_retracted, a boolean over a state space with at least four values, so it cannot express an expression of concern, a correction or a reinstatement — it reports them as false, which reads as “fine”.

Abstract

High Resolution Image Download MS PowerPoint Slide Free chlorine is widely used in industry as a bleaching and oxidizing agent. Its concentration is tightly monitored to avoid environmental contamination and deleterious human health effects. Here, we demonstrate a solid state chemiresistive sensor using graphene like carbon (GLC) to detect free chlorine in water. A 15–20 nm thick GLC layer on a PET substrate was modified with a redox-active aniline oligomer (phenyl-capped aniline tetramer, PCAT) to increase sensitivity, improve selectivity, and impart fouling resistance. Both the bare GLC sensor and the PCAT-modified GLC sensor can detect free chlorine continuously and, unlike previous chemiresistive sensors, do not require a reset. The PCAT-modified sensor showed a linear response with a slope of 13.89 (mg/L) −1 to free chlorine concentrations between 0.2 and 0.8 mg/L which is relevant for free chlorine monitoring for drinking water and wastewater applications. The PCAT-modified GLC sensors were found to be selective and showed less than 0.5% change in current in response to species such as nitrates, phosphates and sulfates in water. They also were resistant to fouling from organic material and showed only a 2% loss in signal. Tap water samples from residential area were tested using this sensor which showed good agreement with standard colorimetric measurement methods. The GLC and PCAT-GLC sensors show high sensitivity and excellent selectivity to free chlorine and can be used for continuous automated monitoring of free chlorine.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

The record

Venue
ACS Sensors
Topic
Analytical Chemistry and Sensors
Field
Chemical Engineering
Canadian institutions
BP (Canada)McMaster University
Funders
Natural Sciences and Engineering Research Council of CanadaCanada Research Chairs
Keywords
ChlorineChemistryOxidizing agentDetection limitSelectivityGrapheneTap waterInorganic chemistryMaterials scienceChromatographyNanotechnologyOrganic chemistry
Has abstract in OpenAlex
yes