MétaCan
Menu
Back to cohort
Record W2784783790 · doi:10.1063/1.5045578

Ultrafast extreme ultraviolet photoemission without space charge

2018· article· en· W2784783790 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

fundA Canadian funder is recorded on the work.
no affNo Canadian affiliation: this work is invisible to an affiliation-only frame.
No Canadian affiliation. An affiliation-only frame, the usual design, would never have seen this work. It is one of the works that make the case for inverting the frame.

Bibliographic record

VenueStructural Dynamics · 2018
Typearticle
Languageen
FieldPhysics and Astronomy
TopicLaser-Matter Interactions and Applications
Canadian institutionsnot available
FundersLawrence Berkeley National LaboratoryAir Force Office of Scientific ResearchCentral Laser Facility, Science and Technology Facilities CouncilBasic Energy SciencesU.S. Air ForceOffice of ScienceNational Institutes of HealthUniversity of British ColumbiaU.S. Department of Energy
KeywordsUltrashort pulseExtreme ultravioletUltravioletSpace (punctuation)PhysicsCharge (physics)Space chargeMaterials scienceAtomic physicsComputer scienceOptoelectronicsOpticsElectronLaserNuclear physicsQuantum mechanics

Abstract

fetched live from OpenAlex

Time- and Angle-resolved photoelectron spectroscopy from surfaces can be used to record the dynamics of electrons and holes in condensed matter on ultrafast time scales. However, ultrafast photoemission experiments using extreme-ultraviolet (XUV) light have previously been limited by either space-charge effects, low photon flux, or limited tuning range. In this article, we describe XUV photoelectron spectroscopy experiments with up to 5 nA of average sample current using a tunable cavity-enhanced high-harmonic source operating at 88 MHz repetition rate. The source delivers >1011 photons/s in isolated harmonics to the sample over a broad photon energy range from 18 to 37 eV with a spot size of 58 × 100 μm2. From photoelectron spectroscopy data, we place conservative upper limits on the XUV pulse duration and photon energy bandwidth of 93 fs and 65 meV, respectively. The high photocurrent, lack of strong space charge distortions of the photoelectron spectra, and excellent isolation of individual harmonic orders allow us to observe laser-induced modifications of the photoelectron spectra at the 10−4 level, enabling time-resolved XUV photoemission experiments in a qualitatively new regime.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.241
Threshold uncertainty score0.997

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0040.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.266
Teacher spread0.256 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it