MétaCan
Menu
Back to cohort
Record W2784872352 · doi:10.1149/ma2018-01/43/2479

Time-of-Flow Micromechanical Mass Spectrometry and Micromechanical Infrared Spectroscopy Using Microfluidic Cantilever

2018· article· en· W2784872352 on OpenAlexaff
Thomas Thundat, Rosmi Abraham, Faheem Khan, Seokbeom Kim, Jungchul Lee

Bibliographic record

VenueECS Meeting Abstracts · 2018
Typearticle
Languageen
FieldPhysics and Astronomy
TopicMechanical and Optical Resonators
Canadian institutionsUniversity of Alberta
Fundersnot available
KeywordsCantileverMicrofluidicsBiomoleculeMass spectrometryNanotechnologyCapillary electrophoresisCapillary actionMaterials scienceChemistryAnalytical Chemistry (journal)ChromatographyComposite material

Abstract

fetched live from OpenAlex

A microfabricated, high resonance frequency cantilever operating in vacuum with a high quality factor can detect changes in its mass with unprecedented sensitivity into sub-femtogram and beyond. However, severe damping of a resonating cantilever in a liquid media reduces it mass sensitivity when operated in a liquid restricting its use as a mass sensor for biomolecules in their native states. Recent developments in the fabrication of cantilevers, with embedded microfluidic channels, however, enable their operation in vacuum conditions. Since this microfluidic cantilever is operated in vacuum, it allows high sensitivity mass-based detection of biomolecules in the confined liquid inside the fluidic channel. Although biomolecular detection based on mass using microfluidic cantilever is extremely sensitive, it cannot provide any molecular selectivity. Therefore, separation of biomolecules prior to detection is an essential condition for this sensing approach. Separation of biomolecules by capillary gel electrophoresis is well-established method, but it is technically challenging for micron-sized systems such as microfluidic cantilever. For example, uniformly immobilizing the stationary phase inside cantilever channel is a challenge due to its extreme small size. In addition, ultra-low ionic conductivity of integrated channels makes it difficult to realize charge-based separation of mixed molecules even at the time scale of several hours. However by coupling a microfluidic cantilever with capillary electrophoresis, it is possible to develop a time-of-flow mass spectrometer that can detect separated biomolecules in their native state. Recently we demonstrated such an electrophoresis assisted time-of-flow mass spectrometer using ‘U’ shaped hollow nanomechanical resonators (HNR). By combining an external capillary electrophoresis arrangement with the HNR based mass detection, it is possible to overcome the low ionic conductivity of channels embedded in the HNR preventing direct in-situ electrophoretic separation. The flow of separated biomolecules through the HNR was achieved by balancing the hydrodynamic pressure to override the electromotive force and inhibit the motion of analytes towards the anode for capillary electrophoresis. As the separated biomolecules go through the HNR, the resonance frequency changes sensitively, providing a frequency-time plot (mass-time plot). With a resonance frequency of around 1.5 MHz, the HNR could detect complex samples, such as egg white proteins, in the molecular weight range of 14-250 kDa. Through integrated separation and detection mechanism, this method has the potential to provide precise and fast detection of separated biomolecules in their native state compared to conventional mass spectrometry. This technique also eliminates the need for staining used in conventional polyacrylamide gel electrophoresis. Finally, since the microfluidic cantilevers can be vacuum packaged as a chip, this technique eliminate the need for vacuum pumps, which has been the main bottleneck in the miniaturization of mass spectrometers. These cantilevers also can be fabricated as bi-material microfluidic cantilevers (BMC) to detect extremely small changes in their temperature. Illuminating the BMC with a tunable wavelength quantum cascade laser (operating in the mid-infrared region) can selectively excite the molecules in the channel. Non-radiative decay of the excited molecules results in the generation of thermal energy, which can be observed as the cantilever bending. A plot of the cantilever bending as a function of the illuminating wavelength shows the IR absorption peaks of the molecules. These nanomechanical IR spectra can be used for unique identification of molecules. Therefore, by combining the liquid-based micromechanical mass spectrometry with the mid-infrared micromechanical spectroscopy offers a novel platform for molecular recognition of biomolecules in their native state. This concept paves the way towards the development of low-cost and on-chip mass spectrometers with ultra-miniaturized dimensions for field applications where the sample consumption is just under a nanoliter.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Insufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.061
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.249
Teacher spread0.237 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2018
Admission routes1
Has abstractyes

Explore more

Same venueECS Meeting AbstractsSame topicMechanical and Optical ResonatorsFrench-language works237,207