Pharmacokinetics and Pharmacodynamics of Ionis-FXIRx, an Antisense Inhibitor of Factor XI, in Patients with End-Stage Renal Disease on Hemodialysis
Bibliographic record
Abstract
Abstract BACKGROUND Patients with end-stage renal disease (ESRD) on hemodialysis are at high risk of both thrombotic and bleeding events. Experimental and clinical data indicate that reducing factor XI (FXI), a key component of the intrinsic pathway, prevents thrombosis without causing bleeding. FXI activity can be lowered with IONIS-FXIRx, a 2nd generation antisense oligonucleotide that specifically reduces human FXI mRNA expression in the liver. This study sought to determine the safety, pharmacokinetics (PK) and pharmacodynamics (PD) of IONIS-FXIRx in participants with ESRD. METHODS In this Phase 2 multicenter study, we enrolled a total of 49 ESRD patients: (A) 6 participants receiving chronic in-center hemodialysis (HD) to receive an open-label single-dose of 300 mg IONIS-FXIRx either 5 minutes before or 10 minutes after HD and assessed the effects of HD on peak (Cmax) and the extent of exposure (AUC0-24hr) parameters of IONIS-FXIRx and (B) another 43 participants in a double-blind design to one of two multiple-dose regimens (200 mg or 300 mg) IONIS-FXIRx or placebo for 12 weeks with 12 weeks of additional follow up. In the double-blind portion, IONIS-FXIRx was administered subcutaneously ~10 minutes after HD. For PK, plasma trough concentration and apparent elimination half-life (t1/2λz) were evaluated. The PD parameters including FXI activity and antigen, aPTT, prothrombin time (PT), and INR were evaluated in the per-protocol population (N= 34) that was defined as all participants who received the complete protocol-specified administration of IONIS-FXIRx or placebo through week 8 and who did not have any major protocol violations. The rate and frequency of clotting on the HD filters and circuit were qualitatively measured with a clotting scale as an exploratory PD analysis. RESULTS The PK cohort included 6 males (5 white) with a mean age of 61 years. The plasma PK profile of IONIS-FXIRx was not significantly altered whether injected before or after HD. After multiple dosing, plasma Cmax values were dose-dependent and similar between Day 1 (first dose) and Day 78 (last dose), suggesting no accumulation of IONIS-FXIRx in ESRD participants after 12-weeks of dosing. After treatment cessation, IONIS-FXIRx had an apparent elimination half-life of approximately 2 weeks. In the double-blind portion of the study, 22 (51.2%) of the participants were male, 24 (55.8%) were white and the mean age was 59 years. Attenuation of FXI activity was associated with a reduction in the incidence of severe clotting events on both the air filter and dialyzer (Table). The reduction in severe clotting events was observed when FXI activity was CONCLUSIONS This study demonstrated that (i) HD had no effect on IONIS-FXIRx PK, (ii) IONIS-FXIRx was well tolerated and produced sustained, and dose-dependent reductions in FXI antigen and activity, and (iii) IONIS-FXIRx reduced severe dialysis circuit clotting events beyond standard heparin use. Collectively, these data support further evaluation of IONIS-FXIRx as a potentially safe, effective antithrombotic therapy in ESRD patients on HD. Download : Download high-res image (269KB) Download : Download full-size image Table 1 . Disclosures Bethune: Ionis Pharmaceuticals: Employment. Walsh: Population Health Research Institute: Employment; Ionis Pharmaceuticals: Consultancy. Jung: Ionis Pharmaceuticals: Employment. Yu: Ionis Pharmaceuticals: Employment. Geary: Ionis Pharmaceuticals: Employment. Bhanot: Ionis Pharmaceuticals: Employment.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.001 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".