MétaCan
Menu
Back to cohort
Record W2789448988 · doi:10.1177/1526602818757012

Distal Placement of Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA) to Restore Hemodynamic Stability in a Patient With Proximal Aortic Rupture

2018· article· en· W2789448988 on OpenAlexaff
Shira A. Strauss, Paul T. Engels, John Harlock

Bibliographic record

VenueJournal of Endovascular Therapy · 2018
Typearticle
Languageen
FieldMedicine
TopicTrauma, Hemostasis, Coagulopathy, Resuscitation
Canadian institutionsHamilton Health SciencesMcMaster University
Fundersnot available
KeywordsMedicineAortaPseudoaneurysmSurgeryStentThoracic aortaBalloon catheterOcclusionBalloonHemodynamicsAnesthesiaComplication

Abstract

fetched live from OpenAlex

PURPOSE: To report unconventional use of the resuscitative endovascular balloon occlusion of the aorta (REBOA) technique to restore hemodynamic stability in a patient who was hemorrhaging from aortic injury proximal to the target zone of occlusion. CASE REPORT: A 72-year-old woman underwent urgent thoracic stent-graft repair of a ruptured 8×8-cm mycotic pseudoaneurysm. Two months later, follow-up imaging revealed that the proximal aortic stent seal zone had degenerated, so a percutaneous procedure was performed 2 months later to preemptively reinforce the segment of stented aorta. Shortly after obtaining femoral access, the patient's condition abruptly deteriorated with profound hypotension, presumably a result of an access complication. REBOA was established in the supraceliac aorta, which sustained the mean arterial pressure while the anesthesiologist resuscitated the patient. Unexpectedly, angiography showed a rupture of the descending thoracic aorta immediately proximal to the upper stent-graft. Balloon inflation distal to the rupture site was maintained while the patient's hypotension was treated. Another stent-graft was quickly placed over the area of concern, overlapping proximal to the prior grafts. Once the aortic perforation was sealed, the patient stabilized hemodynamically. Inotropic support was weaned, and the REBOA occlusion catheter was deflated. Final angiograms of the arch and thoracic aorta confirmed no extravasation; angiograms of the infrarenal aorta and iliac arteries showed no evidence of injury. CONCLUSION: This case illustrates that applying REBOA distal to the injury site in certain clinical scenarios may sufficiently increase peripheral resistance to compensate temporarily for cardiovascular collapse secondary to aortic injury.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.535
Threshold uncertainty score0.734

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.268
Teacher spread0.252 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2018
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Endovascular TherapySame topicTrauma, Hemostasis, Coagulopathy, ResuscitationFrench-language works237,207