MétaCan
Menu
Back to cohort
Record W2791441280 · doi:10.1097/imi.0000000000000462

Suprasternal Transcatheter Aortic Valve Replacement in Patients with Marginal Femoral Access

2018· article· en· W2791441280 on OpenAlexaff
Andy C. Kiser, Thomas G. Caranasos, Mark D. Peterson, David Holzhey, Philipp Kiefer, L. Wiley Nifong, Michael A. Borger

Bibliographic record

VenueInnovations Technology and Techniques in Cardiothoracic and Vascular Surgery · 2018
Typearticle
Languageen
FieldMedicine
TopicCardiac Valve Diseases and Treatments
Canadian institutionsUniversity of TorontoSt. Michael's Hospital
Fundersnot available
KeywordsMedicineCardiologyValve replacementInternal medicineSurgeryStenosis

Abstract

fetched live from OpenAlex

OBJECTIVE: Recently, the PARTNER 2A trial reported results of transcatheter aortic valve replacement versus surgical aortic valve replacement in 2032 intermediate-risk patients at 2 years. Two hundred thirty-six patients (24%) required an access route other than transfemoral. Compared with transfemoral and surgical aortic valve replacement, nontransfemoral transcatheter aortic valve replacement was associated with a numerically higher rate of death and disabling stroke at 30 days. This underscores the need for a better alternative surgical approach for patients with marginal femoral access. We reviewed our multicenter experience with minimally invasive suprasternal transcatheter aortic valve replacement. METHODS: Consecutive patients with symptomatic severe aortic stenosis at high or intermediate risk for surgical aortic valve replacement underwent suprasternal transcatheter aortic valve replacement. A commercially available transcatheter heart valve was deployed under fluoroscopic guidance through the innominate artery or ascending aorta. Using a 3-cm skin incision just above the sternal notch, the Aegis Transit System (Aegis Surgical Ltd, Galway, Ireland) provided illuminated access to the mediastinum without bone disruption. Through a purse-string suture placed in the innominate artery or ascending aorta, transcatheter aortic valve replacement proceeded similarly to the direct aortic approach. RESULTS: Thirty patients at six medical centers successfully underwent suprasternal transcatheter aortic valve replacement. Implanted valves included 2 CoreValve and 12 Evolut-R (Medtronic, Inc, Minneapolis, MN USA), as well as 10 SAPIEN 3 and 6 SAPIEN XT (Edwards Lifesciences, Corp, Irvine, CA USA) with sizes ranging from 23 to 31 mm. Median procedure time was 90 minutes and median hospital stay was 4 days. Postoperatively, new permanent pacemaker (n = 3) was the most common Vascular Academic Research Consortium 2 complication. CONCLUSIONS: These data demonstrate the early clinical feasibility of suprasternal transcatheter aortic valve replacement. Key advantages of this approach include direct access to the innominate artery and ascending aorta, precise sheath control, and confident arterial closure. Additional experience is warranted to confirm these favorable results.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Non-randomized trial · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.328
Teacher spread0.314 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNon-randomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2018
Admission routes1
Has abstractyes

Explore more

Same venueInnovations Technology and Techniques in Cardiothoracic and Vascular SurgerySame topicCardiac Valve Diseases and TreatmentsFrench-language works237,207