MétaCan
Menu
Back to cohort
Record W2791627351 · doi:10.1097/icl.0000000000000496

Ocular Impression-Taking—Which Material Is Best?

2018· article· en· W2791627351 on OpenAlexaff
Jennifer M. Turner, Christine Purslow, Paul J. Murphy

Bibliographic record

VenueEye & Contact Lens Science & Clinical Practice · 2018
Typearticle
Languageen
FieldMedicine
TopicOcular Surface and Contact Lens
Canadian institutionsUniversity of Waterloo
Fundersnot available
KeywordsMedicineOphthalmologyImpressionVisual acuityStainingSurgeryPathology

Abstract

fetched live from OpenAlex

OBJECTIVES: To assess the efficacy and effect on clinical signs of a polyvinylsiloxane (Tresident; Shütz Dental Group GmbH, Germany) compared with an irreversible hydrocolloid (Orthoprint; Zhermack SpA, Badia Polesine, Italy) for ocular impression-taking. METHODS: Twenty subjects were recruited (13 female and 7 male), with mean age 31.1±4.6 years (SD) (range 25.8-39.7). Subjects attended for 2 sessions, each of 1-hr duration, on 2 separate days. Each session was scheduled at the same time on each day. At each visit, the subject underwent an ocular impression procedure, using either Tresident or Orthoprint, in random order and to one eye only. Investigator 2 was blind to this assignment. Two experienced practitioners conducted the study, investigator 1 performed the ocular impression procedures and investigator 2 observed and assessed the clinical signs: logMAR visual acuity, ocular surface staining, tear break-up time (TBUT), and ocular hyperemia. RESULTS: Visual acuity was unaffected by either material; TBUT was marginally disrupted by both materials, but was not clinically significant according to published criteria; ocular redness increased with both materials; and corneal staining was significantly greater after Orthoprint impression. Less redness and clinically insignificant staining after impression-taking, with fewer clinical complications, was found after use of Tresident. CONCLUSIONS: Tresident offers a quicker, more effective, and clinically viable method of obtaining ocular impression topography compared with the traditional Orthoprint, and Orthoprint causes significantly more superficial punctuate staining of the corneal epithelium than Tresident.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.005
Threshold uncertainty score0.018

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.002
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0000.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0050.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.062
GPT teacher head0.435
Teacher spread0.373 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2018
Admission routes1
Has abstractyes

Explore more

Same venueEye & Contact Lens Science & Clinical PracticeSame topicOcular Surface and Contact LensFrench-language works237,207