Bibliographic record
Abstract
Surface coating of hydrous iron aluminum oxide on Ottawa sand was investigated as a means of improving the removal of Cryptosporidium oocysts from water by filtration. Coating the sand increased the zeta potential from −40 to +45 mV at pH 7.0, increasing the potential for interaction with the negatively charged (−25 mV at pH 7.0) Cryptosporidium oocysts. Water seeded with Cryptosporidium oocysts was passed through parallel columns of uncoated and coated sand at superficial velocities of 200–800 m/d (3.5–14 gpm/sq ft) and column lengths of 100–400 mm (4–16 in.). In every trial, coated sand removed significantly more oocysts than uncoated sand. Filter coefficients of coated sand were 2.9 times as high as those of uncoated sand, indicating that coating can significantly improve the removal of Cryptosporidium by granular media filters.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.001 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.001 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".