MétaCan
Menu
Back to cohort
Record W2792582946 · doi:10.1117/12.2292918

CT investigation of patient-specific phantoms with coronary artery disease

2018· article· en· W2792582946 on OpenAlexaff
Lauren Shepard, K. Sommer, Erin Angel, Vijay Iyer, Michael F. Wilson, Frank J. Rybicki, Dimitrios Mitsouras, Sabee Molloi, Ciprian N. Ionita

Bibliographic record

VenueMedical Imaging 2018: Physics of Medical Imaging · 2018
Typearticle
Languageen
FieldEngineering
TopicAdvanced X-ray and CT Imaging
Canadian institutionsOttawa HospitalUniversity of Ottawa
Fundersnot available
KeywordsPulsatile flowImaging phantomMedicineCoronary artery diseaseCoronary arteriesFractional flow reserveBiomedical engineeringBlood flowArteryRadiologyNuclear medicineCoronary angiographyCardiologyMyocardial infarction

Abstract

fetched live from OpenAlex

Purpose: To develop coronary phantoms that mimic patient geometry and coronary blood flow conditions for CT imaging optimization and software validation. Materials and Methods: Five patients with varying degrees of coronary artery disease underwent 320-detector row coronary CT angiography (Aquilion ONE, Canon Medical Systems). The aorta and coronary arteries were segmented using a Vitrea Workstation (Vital Images). Patient anatomy was manipulated in Autodesk Meshmixer and 3D printed in Tango+, a flexible polymer, using an Eden260V printer (Stratasys). Phantoms were connected to a pump that simulates physiologic pulsatile flow waveforms, correlated with a simulated ECG signal. Distal resistance was optimized for all three coronary vessels until physiologically accurate flow rates and pressure were observed. Phantoms underwent coronary CT Angiography (CTA) using a standard acquisition protocol and contrast mixed in the flow loop. Image data from the phantoms were input to a CT-FFR research software and compared to those derived from the clinical data. Results: All five patient-specific phantoms were successfully imaged with CTA and the images were analyzed by the CTFFR software. The phantom CT-FFR results had a mean difference of -5.4% compared to the patient CT-FFR results. Patient and phantom CT-FFR agreed for all three coronary vessels, with Pearson correlations r = 0.83, 0.68, 0.62 (LAD, LCX, RCA). Conclusions: 3D printed patient-specific phantoms can be manipulated through material properties, flow regulations, and a pulsatile waveform to create accurate flow conditions for CT based experimentation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.004
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.008
GPT teacher head0.232
Teacher spread0.224 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2018
Admission routes1
Has abstractyes

Explore more

Same venueMedical Imaging 2018: Physics of Medical ImagingSame topicAdvanced X-ray and CT ImagingFrench-language works237,207