MétaCan
Menu
Back to cohort
Record W2793591672 · doi:10.3847/1538-4365/aae436

The EBEX Balloon-borne Experiment—Detectors and Readout

2018· article· en· W2793591672 on OpenAlexafffund
Maximilian H. Abitbol, Asad M. Aboobaker, P. A. R. Ade, Derek Araujo, François Aubin, C. Baccigalupi, Chaoyun Bao, Daniel Chapman, Joy Didier, M. Dobbs, Stephen Feeney, Christopher Geach, W. Grainger, Shaul Hanany, Kyle Helson, Seth Hillbrand, G. C. Hilton, Johannes Hubmayr, K. D. Irwin, A. H. Jaffe, Bradley R. Johnson, T. J. Jones, Jeff Klein, Andrei Korotkov, Adrian V. Lee, L. J. Levinson, M. Limon, Kevin MacDermid, Amber Miller, Michael Milligan, Kate Raach, Britt Reichborn-Kjennerud, C. D. Reintsema, Ilan Sagiv, G. Smecher, Gregory S. Tucker, Benjamin Westbrook, Karl Young, Kyle Zilic

Bibliographic record

VenueThe Astrophysical Journal Supplement Series · 2018
Typearticle
Languageen
FieldPhysics and Astronomy
TopicDark Matter and Cosmic Phenomena
Canadian institutionsCanadian Institute for Advanced ResearchMcGill University
FundersScience and Technology Facilities CouncilNatural Sciences and Engineering Research Council of CanadaEuropean CommissionFlatiron HealthRhode Island Space Grant ConsortiumCanada Research ChairsNational Aeronautics and Space AdministrationNational Science Foundation
KeywordsBalloonDetectorPhysicsComputer scienceOpticsMedicineSurgery

Abstract

fetched live from OpenAlex

Abstract EBEX was a long-duration balloon-borne experiment to measure the polarization of the cosmic microwave background. The experiment had three frequency bands centered at 150, 250, and 410 GHz and was the first to use a kilopixel array of transition edge sensor bolometers aboard a balloon platform. We describe the design and characterization of the array and the readout system. From the lowest to highest frequency, the median measured detectors’ average thermal conductances were 39, 53, and 63 pW/K, the medians of transition temperatures were 0.45, 0.48, and 0.47 K, and the medians of normal resistances were 1.9, 1.5, and 1.4 Ω; we also give the measured distributions. With the exception of the thermal conductance at 150 GHz, all measured values are within 30% of their design. We measure median low-loop-gain time constants τ 0 = 88, 46, and 57 ms. Two measurements of bolometer absorption efficiency gave results consistent within 10% and showing high (∼0.9) efficiency at 150 GHz and medium (∼0.35 and ∼0.25) efficiency at the two higher bands. We measure a median total optical power absorbed of 3.6, 5.3, and 5.0 pW. EBEX pioneered the use of the digital version of the frequency domain multiplexing system. We multiplexed the bias and readout of 16 bolometers onto two wires. The median per-detector noise-equivalent temperatures are 400, 920, and 14,500 . We compare these values to our preflight predictions and to a previous balloon payload. We discuss the sources of excess noise and the path for a future payload to make full use of the balloon environment.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0010.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.234
Teacher spread0.228 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations24
Published2018
Admission routes2
Has abstractyes

Explore more

Same venueThe Astrophysical Journal Supplement SeriesSame topicDark Matter and Cosmic PhenomenaFrench-language works237,207