MétaCan
Menu
Back to cohort
Record W2793962917 · doi:10.21037/aes.2018.ab083

AB083. Intraocular lens biocompatibility: a novel, objective approach

2018· article· en· W2793962917 on OpenAlexaff
Christina Mastromonaco, Matthew Balazsi, Evangelina Espósito, Jacqueline Coblentz, Siblini Aya, Jade Lasiste, Miguel N. Burnier

Bibliographic record

VenueAnnals of Eye Science · 2018
Typearticle
Languageen
FieldMedicine
TopicIntraocular Surgery and Lenses
Canadian institutionsMcGill UniversityMcGill University Health Centre
Fundersnot available
KeywordsBiocompatibilityIntraocular lensLens (geology)OphthalmologyOptometryMedicineMaterials scienceOpticsPhysics

Abstract

fetched live from OpenAlex

Background: Understanding factors that contribute to posterior capsular opacification (PCO) development is a significant public concern as treatment can lead to complications. In order to prevent PCO, a better understanding of intraocular lens (IOL) characteristics, including design and material, and patient interaction is required. Herein, we performed a retrospective multivariable analysis to determine which factors (IOL and patient based) were least likely to result in PCO. Methods: One hundred eighty post-mortem eyes with implanted IOLs were collected from the Minnesota Eye Bank, along with clinical history, including date of cataract surgery and IOL model number. The capsular bag (CB) with the IOL implant was removed from all eyes to obtain digital images. PCO outcome was quantified on CB images using an objective, automated custom image analyzer (Medical Parachute Automated Detector Opacification Software). The software measured intensity and area of the opacification within the IOL optic edge, intra-optic edge (IOE = intensity/area), and in Soemmering’s ring (SR = intensity/area). Epidemiologic analysis assessed which IOL characteristics and patient-related factors correlated with PCO. IOL factors included material, edge design, lens filter, company, IOL model, decentration and time from cataract surgery to death. Patient factors included sex, age and diabetes, among others. Results: Multivariate analyses showed non-diabetic patients had less PCO (P=0.05). Individuals 50–80 years old compared to 80+ had lower SR PCO (P=0.04). Non-blue light filter IOLs had lower SR and IOE PCO compared to filter IOLs (P=0.03, 0.001). Square and frosted optic edge design had lower SR and IOE PCO rates compared to OptiEdge and round optic edge design (P=0.002, 0.02). The IOL model that had the least PCO was the ZA9003 model, but this was only significant for SR and not IOE PCO (P=0.04). Adjusting for patient-factors, IOL lens model was no longer a confounding factor for PCO. Patients with an IOL implanted for <7 years had lower SR PCO, whereas lower IOE PCO was only seen in implants <4 years old (P=0.0001, 0.04). Conclusions: In order to generate a lens that does not develop PCO, it is critical to understand the IOL- and patient-related factors that lead to PCO development. Based on our data, the most susceptible patients are elderly and diabetic, and it may be preferable to implant a square and frosted edge lens without blue-light filtering in this cohort.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.074
Threshold uncertainty score0.943

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.003
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.094
GPT teacher head0.366
Teacher spread0.273 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2018
Admission routes1
Has abstractyes

Explore more

Same venueAnnals of Eye ScienceSame topicIntraocular Surgery and LensesFrench-language works237,207